Burner and nozzle characteristics tables
5.3 Positioning
This appliance may be installed next to
walls, one of which must be higher than the
worktop, at a minimum distance of
X
mm
from the side of the appliance, as shown in
figures “
A
” and “
C
” relative to the
installation classes.
Any wall units positioned above the
worktop of the appliance must be at a
minimum distance of at least Y mm. If a
hood is installed above the hob, refer to the
hood instruction manual to ensure the
correct clearance is left.
Natural gas G20 - 20 mbar
AUX
SR
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.5
Nozzle diameter (1/100 mm)
72
97
134
Pre-chamber (printed on nozzle)
(X)
(Z)
(F3)
Reduced flow rate (W)
400
500
1600
LPG G30/31 - 30/37 mbar
AUX
SR
UR-3c
Rated heating capacity (kW)
1.05
1.8
3.5
Nozzle diameter (1/100 mm)
50
65
94
Pre-chamber (printed on nozzle)
-
-
-
Reduced flow rate (W)
400
500
1600
Rated flow rate G30 (g/h)
76
131
255
Rated flow rate G31 (g/h)
75
129
250
Heavy appliance
Crushing hazard
• Position the appliance into the cabinet
cut-out with the help of a second person.
Pressure on the open door
Risk of damage to the appliance
• Never use the oven door to lever the
appliance into place when fitting.
• Avoid exerting too much pressure on the
door when open.
Heat production during appliance
operation
Risk of fire
• Veneers, adhesives or plastic coatings
on adjacent furniture should be
temperature-resistant (not less than
90 °C).
X
150 mm
Y
750 mm