32
Instructions for the installer
11. ADAPTATION TO DIFFERENT TYPES OF GAS
BEFORE PERFORMING ANY OPERATIONS, SWITCH OFF THE POWER SUPPLY TO THE
APPLIANCE.
Appliance set for gas:
LPG G30/G31
pressure 28/37
mbar
(see label on product)
In the case of operation with other types of gas, the burner nozzles must be changed and the minimum
flame adjusted on the gas taps.
To change the nozzles, proceed as described in the following paragraphs.
11.1 Replacing the hob nozzles
1 Remove the pan stands, and remove all burner caps
and flame-spreader crowns to access the burner
casings.
2 Unscrew the nozzles using a 7 mm socket wrench.
3 Replace the burner nozzles according to the type of gas
to be used (see 11.6 Burner and nozzle characteristics
table).
4 Replace the burners in the correct position.
11.2 Replacing the bottom burner's nozzle
1 Remove all accessories from inside the oven (such as
trays, racks etc.).
2 Lift up the oven base and pull it outwards as shown in
the figure.
3 Unscrew the fastening screws
A
and
B
completely.
4 Move away the lock that secures the thermocouple and
igniter fastened by screw
A
.
5 Slide the burner outwards until the nozzle is accessible.
6 Using a 7 mm socket wrench, replace the nozzle,
inserting a new nozzle suitable for the type of gas to be
used (see “11.6 Burner and nozzle characteristics
table”).
B
A