Installation
72
Burner and nozzle characteristics tables
The nozzles not provided are available at Authorised Service Centres.
Natural Gas G20 - 20 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.9
3.5
Nozzle diameter (1/100 mm)
72
94
115
133
Pre-chamber (printed on nozzle)
(X)
(Y)
(Y)
(S)
Reduced flow rate (W)
400
500
800
1600
Natural Gas G25 - 25 mbar / G25.3 - 25 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.8
2.9
3.5
Nozzle diameter (1/100 mm)
72
94
121
138
Pre-chamber (printed on nozzle)
(F1)
(Y)
(F2)
(F3)
Reduced flow rate (W)
400
500
800
1600
LPG G30/31
-
30/30 mbar
AUX
SR
R
UR
Rated heating capacity (kW)
1.0
1.75
2.9
3.5
Nozzle diameter (1/100 mm)
50
65
85
94
Pre-chamber (printed on nozzle)
-
-
-
-
Reduced flow rate (W)
400
500
800
1600
Rated flow rate G30 (g/h)
73
127
211
254
Rated flow rate G31 (g/h)
71
125
207
250
Appliance set for:
G+ Groningen Group K gas
G25 (2L) - 25 mbar
G25.3 (2K) - 25 mbar