background image

 

 

Instructions for the installer

 

 

 

31 

6.

 

FINAL OPERATIONS 

Having carried out the above adjustments, reassemble the appliance 
following, backwards, the instructions in paragraph “5.1 Removing the 
hob”. 

 
 
 

6.1

 

Regulation of minimum for natural gas 

Replace the components on the burner and slide 
the knobs on the gas tap pins. 
Light the burner and set it at minimum position. 
Remove the knob and turn the regulation screw 
inside or next to the gas tap pin (depending on 
the model) until you get a suitable minimum 
flame. 
Replace the knob and check burner flame 
stability: (rapidly turning the knob from maximum 
to minimum position, the flame should not go 
out). 

 
 
 

6.2

 

Regulation of minimum for LPG 

To regulate the minimum for LPG, completely tighten (clockwise) the 
screw inside or next to the gas tap pin (depending on the model). 
The diameters of the by-passes for each burner are given in table “5.2 
Regulation for LPG”. 

 
 

 

 

 

After having regulated the device with gas other than the one tested, 
replace the label located on the guard with the one that corresponds to 
the new gas. The label is inside the bag that contains the nozzles 
provided. 

 

 

Summary of Contents for SNL97BXG

Page 1: ...B ________________________________________ 33 8 LEANING AND MAINTENANCE ____________________________ 35 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON...

Page 2: ...ER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT...

Page 3: ...PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE COOKING HOB GRIDS DO NOT USE RECIPIENTS OR GRIDDLE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET...

Page 4: ...mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make...

Page 5: ...on a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily re...

Page 6: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 5 mm 2 3 x 1 5 cable keeping in mind...

Page 7: ...s been inspected for G25 2L at a pressure of 25 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 228 1 Conn...

Page 8: ...appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid overheating or excess humidity produc...

Page 9: ...aced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the gri...

Page 10: ...e D to regulate the air flow until distance X is reached indicated in the chart in paragraph 5 4 Regulation of primary air and then secure the tube by means of screw A After the regulations have been...

Page 11: ...of primary air After the regulations have been carried out restore the seals with sealing wax or equivalent material Burner Rated heating capacity kW G25 25 mbar Nozzle diameter 1 100 mm Reduced flowr...

Page 12: ...he model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation o...

Page 13: ...ners on hob BURNERS 1 Auxiliary 2 Semi rapid 3 Rapid 4 Double crown 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it has to be cleaned inside an...

Page 14: ...er burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which permit to use both burners at the same time or to select one or the other as required Th...

Page 15: ...n cm 1 Auxiliary 12 14 2 Semi rapid 16 24 3 Rapid 22 26 4 Double crown 12 30 For burner reference numbers see page 32 7 4 Using a griddle plate A few precautions are necessary if you wish to use a gri...

Page 16: ...rface rinse thoroughly and dry with a soft cloth or deerskin 8 1 2 Food stains or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products a...

Page 17: ...element must be treated with specific cleaning products which are available on the market This necessary operation prevents oxidisation rust formation 8 2 3 The cover Clean the glass or steel cover wh...