background image

Introduction 

 

 

23 

 

 THE IDENTIFICATION PLATE, WITH TECHNICAL DATA, SERIAL 

NUMBER AND MARKING IS CLEARLY VISIBLE UNDER THE CASING. 
THE PLATE ON THE CASING MUST NOT BE REMOVED. 
BEFORE CONNECTING THE DEVICE, MAKE SURE THAT IT HAS 
BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT, 
CHECKING THE LABEL UNDER THE HOB. 

 

   

 DO NOT PUT 

PANS WITHOUT PERFECTLY SMOOTH AND FLAT 

BOTTOMS ON THE COOKING HOB GRIDS. 

 

   

 

  DO NOT USE 

PANS OR GRIDDLE PLATES THAT EXTEND BEYOND 

THE EXTERNAL PERIMETER OF THE HOB. 

 

   

 

 THE HOB IS TO BE USED BY ADULTS ONLY

. DO NOT LET 

UNSUPERVISED CHILDREN PLAY WITH THE HOB. 

 

   

  THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN 

DIRECTIVE 2002/96/EC ON WASTE ELECTRICAL AND ELECTRONIC 
EQUIPMENT (WEEE). 
THIS GUIDELINE IS THE FRAME OF A EUROPEAN-WIDE VALIDITY 
OF RETURN AND RECYCLING ON WASTE ELECTRICAL AND 
ELECTRONIC EQUIPMENT. 

 

   

 

  The manufacturer declines all responsibility

 for damage to persons or 

things caused by non-observance of the above prescriptions or by 
interference with any part of the appliance or by the use of non-original 
spares. 

 

Summary of Contents for SNL574GH

Page 1: ...USING THE HOB______________________________________________ 34 8 CLEANING AND MAINTENANCE_________________________________ 36 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICA...

Page 2: ...CONSIDERED IMPROPER THE MANUFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPE...

Page 3: ...E PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB THIS APPLIANCE IS MARKED ACCORDING TO THE EUROPEAN...

Page 4: ...is classified type Y as regards risks against fire and it can be set adjacent to walls that are higher than the work surface provided that a distance of 145 mm is respected as shown in the figure to p...

Page 5: ...on a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily re...

Page 6: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 0 mm 2 3 x 1 0 cable keeping in mind...

Page 7: ...inspected for G25 2L3B P natural gas at a pressure of 25 mbar For use with other types of gases see Section ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is gas external threaded ISO 7...

Page 8: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Page 9: ...replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the...

Page 10: ...ation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Burner Rated heating capacity LP...

Page 11: ...h sealing wax or equivalent material Burner Rated heating capacity Natural gas G25 25 mbar Nozzle diameter 1 100 mm Reduced flowrate W Auxiliary 1 05 76 380 Semirapid 1 65 98 380 Rapid 2 7 123 650 Rap...

Page 12: ...model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of...

Page 13: ...iary 2 Semirapid 3 Rapid 4 Rapid large 6 Ultra rapid 7 Double crown 8 Fish pan 10 Double crown 6 4 Lubrication of gas taps After a while the gas tap may become hard to turn or lock If this happens it...

Page 14: ...ong one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which allow both bur...

Page 15: ...Diameter of the pans Burners min and max in cm Auxiliary 7 18 Semirapid 10 24 Rapid 12 24 Double crown 22 26 Ultrarapid 22 26 Fish burner Special oval shaped vessels 7 4 Using a griddle plate A few pr...

Page 16: ...ve the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoro...

Page 17: ...ater using a non abrasive detergent taking care to remove all tough spots Before remounting allow the components to fully dry out In fact humidity residues inside the burner holes might impair burner...

Reviews: