Smeg SHI410N1 Instruction Manual Download Page 9

 

 

 

 

EN 

 

9

 

PREPARATION OF THE FRAME FOR THE HOOD IN 

RECYCLING VERSION 

In  case  the  hood  is  used  in  recycling  version  it  is 
necessary  to  prepare  the  frame  with  all  the  necessary 
connection  pieces.  In  order  to  make  the  installation 
easier it is necessary to lengthen the frame: 
•  Unscrew  the  two  screws 

2.1

  fixing  the  upper 

chimney to the frame and pull the chimney out.  

•  Unscrew  the  four  safety  screws  placed  at  the  top  in 

the frame separation area.  (

A

). 

•  Unscrew  the  eight  metric  screws  connecting  the  two 

columns, placed on both sides of the frame (

B

). 

Installation of components in recycling version: 
•  Fix the recycling air outlet piece 

15

 to the upper part 

of the frame using four 

12c

 screws supplied with the 

hood. 

•  Fix  the  flange  (ø120) 

10 

to  the  lower  part  of  the 

recycling air outlet 

15

•  Put the reducer flange 

9

 on the hood body outlet. 

•  At this point, join the flanges with a pipe. In order to 

calculate  the  height  of  the  pipe  it  is  necessary  to 
estimate  the  height  of  the  hood  (mm)  and  subtract 
615 mm. (H pipe = H hood-615). 

•  Lengthen  the  frame  so  that  the  pipe  can  be  inserted. 

Place the pipe between the two flanges and block it. 
Make  sure  that  the  height  of  the  frame  is  correct 
considering the height of the cooker hood (H frame = 
H  hood  –  184).  Adjust  the  height  of  the  frame  and 
tighten  again  the  earlier  removed  screws.  Tighten 
again the safety screws in order to give more stability 
to the structure. 

•  Fix the pipe with the pipe clamps 

25

 

A

B

15

12c

10

Summary of Contents for SHI410N1

Page 1: ...Instructions Manual SHI410X1 SHI410N1 ...

Page 2: ...2 2 INDEX SAFETY INFORMATION 3 CHARACTERISTICS 6 INSTALLATION 8 USE 12 CARE AND CLEANING 13 EN ...

Page 3: ... height please refer to the paragraphs on working dimensions and installation If the instructions for installation of the gas hob specify a greater distance this must be respected Check that the mains voltage corresponds to that indicated on the rating plate fixed to the inside of the hood Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules For Clas...

Page 4: ...to be adopted for fume discharging it is important to closely follow the regulations provid ed by the local authorities WARNING Before installing the Hood remove the protective films Use only screws and small parts supplied with the hood WARNING Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards Do not look directly at the light th...

Page 5: ...ls not applicable to appliances that only discharge the air back into the room The symbol on the product or on its packaging indicates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of elec trical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential ne...

Page 6: ...per frame 7 1b 1 Lower frame 9 1 Reducer Flange ø 150 120 mm 10 1 Flange ø 120 mm 11b 2 Flaps 15 1 Recirculation Air Outlet Connection 25 2 Pipe clamps not included Ref Q ty Installation Components 11 4 Wall Plugs ø 10 12c 4 Screws 2 9 x 6 5 12f 4 Screws M6 x 10 12g 4 Screws M6 x 80 12h 4 Screws 5 2 x 70 21 1 Drilling template 22 4 6 4 mm int dia washers 23 4 M6 nuts Q ty Documentation 1 Instructi...

Page 7: ...EN 7 7 Dimensions 650mm 600mm Dimensions of the hood in ducting version Dimensions of the hood in recycling version ...

Page 8: ...ings with wall thickness of 20 mm drill ø 10 mm immediately insert the Dowels 11 supplied For wooden beam ceilings drill according to the wood screws used For wooden shelf drill ø 7 mm For the power supply cable feed drill ø 10 mm For the air outlet Ducted Version drill according to the diameter of the external air ex haust duct connection Insert two screws of the following type crossing them and ...

Page 9: ...t piece 15 to the upper part of the frame using four 12c screws supplied with the hood Fix the flange ø120 10 to the lower part of the recycling air outlet 15 Put the reducer flange 9 on the hood body outlet At this point join the flanges with a pipe In order to calculate the height of the pipe it is necessary to estimate the height of the hood mm and subtract 615 mm H pipe H hood 615 Lengthen the...

Page 10: ...n the Frame is subjected to lateral stress If the Ceiling is not strong enough in the area where the hood is to be fixed the Installer must strengthen the area using suitable plates and counterplates anchored to re sistant structures 2 1 1 2 Connections AIR OUTLET DUCTING VERSION When installing the Ducting version join the Hood to the outlet duct using a rigid or flexible pipe ø150 or 120 mm sele...

Page 11: ...lling downwards Remove possible charcoal filters In order to fix the hood body to the frame insert the 4 screws 12f in their seats It is necessary to leave at least 4 5 mm gap between the screw heads and the frame plate Hook the hood canopy to the frame and turn it to the left until it reaches the stop then lock the screws immediately to prevent the hood canopy from falling out accidentally 2 1 EL...

Page 12: ...s After 200 working hours all the LEDs L1 L2 L3 L4 will light up and start to flash to indicate saturation of the activated charcoal filters T2 Turn the suction motor on at speed two On T3 Turn the suction motor on at speed three On Press and hold the button for 2 seconds to activate intensive speed This speed is timed to run for 6 minutes At the end of this time the system will automatically retu...

Page 13: ...icularly intensive Resetting the alarm signal Press button T1 see the paragraph on Use Cleaning the Filters Open the lighting unit by pulling on the nocth Remove the Filters one at a time pushing them towards the back of the unit and at the same time pulling downward Wash the Filters without bending them and leave them to dry completely before replacing Replace taking care to ensure that the handl...

Page 14: ...Leds L1 L2 L3 flash twice Activated Charcoal Filter saturation alarm ACTIVATED Leds L1 L2 L3 flash once Activated Charcoal Filter saturation alarm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press button T1 see the paragraph on Use Changing the Filter Open the lighting unit by pulling on the nocth Remove the Metal grease filters Remove the saturated Activated Char...

Page 15: ......

Page 16: ...991 0640 988_ver1 201216 D00007445_00 ...