Instructions for the Installer
61
Operation at 380-415V 3N~:
use a H05RR-F / H05RN-F five-wire
cable (cable of 5 x 2.5 mm
2
).
Operation at 380-415V 2N~:
use a H05RR-F four-wire cable (cable
of 4 x 4 mm
2
).
Operation at 220-240 V~:
use a H05RR-F three-wire cable (cable of
3 x 6 mm
2
).
The earth wire (yellow-green) must be at least 20 mm longer than
the other wires at the end for connection to the appliance.
The power supply cable must be fitted with a suitable five-pin plug (see technical data plate) or, for
appliances operating on
220-240 V
, a three-pin plug. The power supply plug and wall socket must be of
the same type and compliant with the relevant regulations. Check that the appliance is earthed
appropriately. Before putting the appliance into operation, check that the power supply line is properly
earthed. The use of adapters or junctions is not recommended.
THE MANUFACTURER DECLINES ALL RESPONSIBILITY
FOR INJURY OR DAMAGE CAUSED BY
FAILURE TO COMPLY WITH THE ABOVE REGULATIONS