Instructions for the installer
59
10.2 Cable replacement
Should the supply cable need replacing,
remove the back guard by unscrewing the
screws to gain access to the terminal.
Replace the cable. The cable cross-
section must be no less than 1.5 mm² (3 x
1.5) (see 10.1 Electrical connection).
Make sure that the cables (for the oven or
any hob) follow the best route in order to
avoid any contact with the oven.
WARNING: The tightening torque of the screws of the terminal supply wires