Smeg SARV532XS Installation And Operating Instructions Manual Download Page 10

 

 

Instructions for the installer

 

 

 

4. ELECTRICAL CONNECTION 

 

 

Make sure that the voltage and capacity of the power line conform to the 
data shown on the plate located under the casing. Do not remove this 
plate for any reason.
 

 

 

The plug on the end of the supply cable and the wall socket must be the 
same type and conform to the current electrical system regulations. 
Check that the power line is adequately grounded. 

 

 

On the power line, install an omnipolar cut-off device with contact cut-off 
distance greater than or equal to 3 mm, located in an easily accessible 
position near the unit. 

 

 

Do not use reducers, adapters or shunts. 

 
 

 

 

 

 

If the power cable is replaced, the wire section on the new cable must 
not be less than 1.0 mm

2

 (3 x 1.0 cable), keeping in mind that the end to 

be connected to the hob must have the ground wire (yellow-green) 
longer by at least 20 mm. Use only H05V2V2-F cable or similar which has 
a maximum temperature of 90°C. Any replacement needed should be 
carried out by a specialised technician who should make the mains 
connections according to the following diagram. 

 

L = brown 
N = blue 

 = yellow-green 

 

 

 

 
 

 

 

 

The manufacturer will not be liable  for any damage to persons or 
property caused by non-observance of the above instructions or deriving 
from the tampering of even a single part of the hob. 

 

11 

Summary of Contents for SARV532XS

Page 1: ...installation and operating instructions SARV532XS cooktop smeg technology with style...

Page 2: ...ANING AND MAINTENANCE _________________________________ 18 9 PROBLEMS AND CAUSES ______________________________________ 20 Thank you for choosing our product We advise you to read this manual carefull...

Page 3: ...UFACTURER DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CEN...

Page 4: ...LE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONLY DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB REPLACED APPLIANCES MUST BE TAKEN TO A SPECIAL GA...

Page 5: ...elation to fire hazards and can therefore be mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure...

Page 6: ...nstaller Overall dimensions location of gas and electrical connection points all measures in mm 30 CM HOB 70 CM HOB A 60 120 B 90 90 C 30 30 D 90 70 2 2 Clearance above and around domestic appliances...

Page 7: ...ess than 150 mm above the hob for the full dimension width or depth of the cooking surface area Where the cooking appliance is fitted with a splashback protection of the rear wall is not required 3 Ad...

Page 8: ...hat they cannot be obstructed indoors or outdoors and should preferably be close to the floor on the side opposite to the combustion gas discharge point If it is not possible to make the openings in t...

Page 9: ...to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are place...

Page 10: ...cessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 0 mm 2 3 x 1 0 cable keeping in mind tha...

Page 11: ...ed and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the grids...

Page 12: ...never exceed 3 Nm Reposition support B so that nozzle C is covered perfectly Place the burner on its support and ignite it Move the Venturi tube D to regulate the air flow until the flame is stable a...

Page 13: ...ok 4 15 0 1 70 Wok dual control 5 15 0 Outer 11 5 1 50 Inner 3 5 0 85 For burner reference numbers see page 15 6 FINAL OPERATIONS Having carried out the above adjustments reassemble the appliance foll...

Page 14: ...hob Burners 1 Auxiliary 2 Semi rapid 3 6 Rapid 4 Wok 5 Wok dual control 6 3 Lubrication of gas taps With time it may happen that the gas taps get blocked and hard to turn Clean them inside and re gre...

Page 15: ...ponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which permit to use both burners a...

Page 16: ...e to the hob all recipients or griddle plates must be placed within the perimeter of the hob at a distance of 3 4 cm from the knobs All containers have to have a flat and smooth bottom When using fats...

Page 17: ...ns or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products and remove spots or residuals with non scratch sponges or if need be with woo...

Page 18: ...s connection the gas connection must be checked periodically at least every 2 years Each time the cooker is moved the connection may be stressed test it for leakages using special sprays or a solution...

Page 19: ...on the bottom of the pans Defect of comburent air or incorrect injectors Burner dirty or flame ports obstructed Clean the burner Call Service Center if the problem remains The flame is very short and...