Instructions for the installer
17
13.INSTALLATION OF THE APPLIANCE
It is the law that all gas appliances are installed by
competent persons
. Corgi gas installers are
approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must
be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.
This appliance may be installed next to a wall which is higher than the appliance, as shown in the
diagram
showing the correct installation conditions. Any wall cupboards or shelves must be at a distance
of at least
750 mm
above the work surface.
13.1 Electrical connection
The I.D. plate with techinical data, registration number and brand name is visibily positioned in the
storage compartment.
The plate must not be removed
.
If the appliance is connected to the supply by means of a fixed connection, install a multipolar cut-out
device on the line, with contact opening distance equal to or greater than
3 mm
, located near the
appliance and in an easily reachable position.
The connection terminals are located at the rear of the
appliance. For electrical connections see following diagram. To
access, remove the rear cover.
For operation on 380-415V3N :
use an H05RR-F / H05RN-F /
H05V2V2-F type five-core cable (5 x 2.5 mm
2
).
For operation on 380-415V2N :
use an H05RR-F / H05RN-F /
H05V2V2-F type five-core cable (cavo di 4 x 4 mm
2
).
For operation on 220-240V :
use an H05RR-F / H05RN-F /
H05V2V2-F (cavo di 3 x 6 mm
2
).
The cable end to be connected to the appliance must be provided
with an ground wire (yellow-green) at least 20 mm longer.