Installation
22
For 36” models only
• One label for LGP injectors.
• Two injectors
Ø 1.17
mm for the
Dual
Flame
burners (outer ring).
• Two injectors
Ø 0.48
mm for the
Dual
Flame
burners (inner ring).
• Four injectors
Ø 1.02
mm for the
Rapid
burners.
At the end of the conversion procedure
completely fill out the Gas Conversion label
(part no. 92849A078) and attach it to the
rear or bottom of the appliance. Do not
cover any other labels with the Gas
Conversion label.
1.7 Minimum adjustment
For natural Gas
:
Light the burner and turn the knob to the
minimum position. Remove the gas tap knob
and turn the adjustment screw at the side of
the tap rod until the desired minimum flame
is achieved. Refer to the following pictures.
• Dual Flame burner:
• Rapid burner:
Refit the knob and verify the correct ignition
and burner flame stability (when turning the
knob rapidly from the maximum to the
minimum position the flame must not go out).
Repeat this operation on the remaining gas
taps on the cooktop.
For LP Gas
:
Turn off the burners and unplug the
appliance from the electrical power supply.
For regulating the minimum with LP, the
screws at the side of the tap rod must be
turned clockwise all the way. Once the
regulation has been completed, replace the
seal on the by-passes using paint or similar
materials.