background image

 

Instructions for the installer

 

 

10

 

2.3

 

Room ventilation 

 

 

Caution

  –  This  hob  may  only  be  installed  and  operated  in  rooms 

permanently  ventilated  in  accordance  with  current  regulations.  For 

proper operation of a gas appliance it is essential for the air necessary 

for combustion of the gas to be able to flow naturally into the room. Air 

must  flow  directly  into  the  room  through  openings  in  its  outside  walls. 

This  (these)  opening  (s)  must  have  a  free  passage  cross-section  of  at 

least  100  cm

2

,  or  200  cm

2

  for  appliances  not  equipped  with  gas  safety 

device.  These  openings  must  be  constructed  so  that  they  cannot  be 

obstructed  indoors  or  outdoors,  and  should  preferably  be  close  to  the 

floor on the side opposite to the combustion gas discharge point. If it is 

not  possible  to  make  the  openings  in  the  room  where  the  cooker  is 

installed,  the  necessary  air  may  be  taken  from  an  adjoining  room, 

proveded it is not a bedroom or a room with fire risk. 

 

2.4

 

Discharge of combustion products 

 

 

Discharge  of  combustion  products  must  be  guaranteed  by  means  of 

hoods connected to a natural draught flue with certain efficiency, or by 

means of forced aspiration. 

An  efficient  aspiration  system  requires  careful  planning  by  a  specialist 

capable of installing it, respecting the positions and distances prescribed 

by  standards.  After  installation,  the  installer  must  issue  a  certificate  of 

conformity. 

 

Summary of Contents for PV631CNXAU

Page 1: ...________________________________________ 17 8 LEANING AND MAINTENANCE ____________________________ 19 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON TH...

Page 2: ...DECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS...

Page 3: ...ATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB WHERE THIS APPLIANCE IS INSTALLED IN MARINE CRAFT OR IN CARAVANS IT SHALL NOT BE USED AS A SPACE HEATER DO NOT SPRAY AEROSOLS IN THE VICINITY...

Page 4: ...mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make...

Page 5: ...Instructions for the installer 7 Overall dimensions location of gas and electrical connection points all measures in mm A 100 B 350 C 60 D 60...

Page 6: ...ever in no case shall the clearance between the highest part of the hob of the cooking appliance and a range hood be less than 600 mm or for an overhead exhaust fan 750 mm Any other downward facing co...

Page 7: ...stance from the periphery of the nearest burner to a horizontal combustible surface is less than 200 mm then E shall be 10 mm or more or the horizontal surface shall be above the trivet See insets abo...

Page 8: ...that they cannot be obstructed indoors or outdoors and should preferably be close to the floor on the side opposite to the combustion gas discharge point If it is not possible to make the openings in...

Page 9: ...on to allow the gas to be turned off and disconnected for servicing and removal of the appliance as required from the gas supply Before the appliance is operated make certain all relevant parts are pl...

Page 10: ...accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 1 5 mm 2 3 x 1 5 cable keeping in mind...

Page 11: ...laced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the gr...

Page 12: ...The screwing torque of the nozzle should never exceed 3 Nm Reposition support B so that nozzle C is covered perfectly Place the burner on its support and ignite it Move the Venturi tube D to regulate...

Page 13: ...with this type of gas after it has been adjusted for LPG perform the same operations described in paragraph 5 2 Adjustment for LPG but refer to the following table for the proper injectors Burner NG 1...

Page 14: ...Remove the knob and turn the regulation screw inside or next to the gas tap pin depending on the model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly...

Page 15: ...long one corresponding to the small inner burner and a short one to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which permit to us...

Page 16: ...n cm 1 Auxiliary 12 14 2 Semi rapid 16 24 3 Rapid 22 26 4 Double crown 12 30 For burner reference numbers see page 16 7 4 Using a griddle plate A few precautions are necessary if you wish to use a gri...

Page 17: ...rface rinse thoroughly and dry with a soft cloth or deerskin 8 1 2 Food stains or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products a...

Page 18: ...element must be treated with specific cleaning products which are available on the market This necessary operation prevents oxidisation rust formation 8 2 3 The cover Clean the glass or steel cover wh...

Page 19: ......

Page 20: ...914773030 B...

Reviews: