4)

The regulator must be checked at
a minimum water column of at
least 1” W.C. above the set
pressure. The inlet pressure to
the regulator should be as follows
for operation and checking the
regulator setting:

NATURAL GAS

: Set pressure at

4” water column (101.6 mm).

Supply pressure 3 

1

/

2

” - 10 

1

/

2

W.C.

LP GAS

: Set pressure at 11”

W.C. Supply pressure 8”- 13”
W.C. maximum.

5)

Line pressure testing: Testing above 112 PSI (3.5 kPa), with water column of 14” (35.6 cm) (gauge).
The cooktop and its individual shut-off valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures greater than 1/2 psig (3.5 kPa).
Testing below 112 PSI (3.5 kPa) with a water column of 14” (35.6 cm) (gauge) or lower.
The cooktop must be isolated from the gas supply piping system by turning off the respective manual
shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or
less than 1/2 psig (3.5 kPa).

6)

If the appliance is installed on an oven, the gas pipe must not pass
along the back of the oven, as this may cause overheating.

3.4 Electrical requirements 

  WARNING

ELECTRICAL SHOCK HAZARD

-  Plug into a grounded 3-prong outlet.

-  Do not cut or remove the ground prong.

-  Do not use an adaptor.

-  Do not use an extension cord.

-  Failure to follow these instructions can result in death, fire, or electrical

shock.

-  lf codes permit and a separate ground wire is used, it is recommended that the suitability of the

ground path be checked by a qualified electrician.

-  Check with a qualified electrician if you are not sure whether the cooktop is properly grounded. Do

not ground to a gas pipe.

-  A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is required. A time-delay fuse or circuit

breaker is recommended. It is recommended that a separate circuit serving only this appliance be
provided.

Summary of Contents for PS9RU3

Page 1: ...ne Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas s...

Page 2: ...g codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not s...

Page 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS...

Page 4: ...ktop is to be installed must be sealed The cabinet opening dimensions that are shown must be used The given dimensions are the minimum clearances A grounded electrical supply is required See the 3 4 E...

Page 5: ...62 mm 30 MAXIMUM 866 mm 34 3 16 600 mm 23 5 8 330 mm 13 The support strips must be properly sized and fastened so that they can support the appliance Gas line opening Wall everywhere 5 12 7 cm beneath...

Page 6: ...Instructions for the Installer 8 3 2 Type B installation measurements Complete base B1 B2...

Page 7: ...will be used for the passing of the gas connection while the right opening is for the electric connection For the fastening drill 4 holes 8 mm or 5 8 diameter in the positions shown alongside The dist...

Page 8: ...ected to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel...

Page 9: ...f the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an oven t...

Page 10: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Page 11: ...ns in force USE A SOAPY SOLUTION TO CHECK THAT IT IS LEAK TIGHT NEVER USE A FLAME Follow these instructions to leak test the appliance The following procedures must be carried out to adjust the gas su...

Page 12: ...strips so that once they are tightened the cooktop is securely fastened to the structure 2 NOTE Use all of the brackets supplied with the appliance to fasten it to the support structure FASTENING FOR...

Page 13: ...t D supplied between fitting C adaptor E Always place a suitable sealing medium such as Teflon tape between pressure regulator F and adaptor E and between pressure regulator F and pipe G The adaptor C...

Page 14: ...o the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after assembly has been completed and you have checked to ensure that all parts have been fitted properly 1...

Page 15: ...equipped with a three pronge polarized plug grounding which fits in standard three pronged grounding wall outlets WARNING When servicing the controls label all wires prior to disconnection Wiring err...