![Smeg PS9RU3 User Manual Download Page 7](http://html1.mh-extra.com/html/smeg/ps9ru3/ps9ru3_user-manual_1301746007.webp)
Instructions for the Installer
9
DISTANCES
B
C
G
H
I
L
M
MINIMUM
580 mm
22
7
/
8
”
210 mm
8
1
/
4
”
900 mm
35
7
/
16
”
904 mm
35
5
/
8
”
457 mm
18
”
762 mm
30
”
-
MAXIMUM
600 mm
23
5
/
8
”
-
-
-
-
-
330 mm
13
”
CABINET BASE:
Make two openings in the back
of base that have the dimensions
given alongside. The left opening
will be used for the passing of
the gas connection, while the
right opening is for the electric
connection. For the fastening,
drill 4 holes (8 mm or
5
/
8
”
diameter) in the positions shown
alongside.
The distances of the holes and the openings for the connections refer to the cooktop installed
against the rear wall.
Gas line opening
Wall:
everywhere, 5” (12.7 cm) beneath the underside of the countertop.
Grounded outlet
Position within 24” (61 cm) from the right rear corner of the cut out drawer.