Smeg PGFU30X Manual Download Page 6

Instructions for the Installer

8

3.1

Gas supply requirements

WARNING

EXPLOSION HAZARD

-

Use a new AGA- or CSA-approved gas supply line.

-

The supply line must be equipped with a manual shutoff valve. This

valve should be located in the same room but external to the cooktop. It
should be in a location that allows ease of opening and closing. Do not
block access to shutoff valve. The valve is for turning on or shutting off
gas to the cooktop.

-

Securely tighten all gas connections.

-

lf connected to LP, have a qualified technician ensure that gas pressure
does not exceed a 14" water column.

-

Examples of qualified technicians include licensed heating personnel,
authorized gas company personnel, and authorized service personnel.

-

Failure to do so can result in death, explosion, or fire.

NOTE:

- observe all government codes and ordinances.
- The cooktop must be connected to a regular gas supply.

1)

This installation must conform with all local codes and ordinances. In the absence of local codes,

installation must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 -
latest edition or CAN/CGA B149 - latest edition.

2)

If local codes permit, a flexible metal appliance connector with the new AGA- or CSAcertified design, 4-5
feet (1.2-1.5 m) long, 1/2" or 3/4" I.D., is recommended for connecting this cooktop to the gas supply line.
Do not bend or damage the flexible connector when moving the cooktop. The pressure regulator has 3/8
female pipe threads. You will need to determine the fittings required, depending on the size of your gas
supply line, the flexible metal connector and the shut-off valve.

3)

The supply line shall be equipped with an approved shut-off valve.
This valve should be located in the same room as the cooktop and

should be in a location that allows for easy opening and closing.
Do not block access to the shut-off valve. The valve is necessary for
turning the gas to the appliance on or off.

Summary of Contents for PGFU30X

Page 1: ...Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be perfo...

Page 2: ...nment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do n...

Page 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS...

Page 4: ...ir downward toward the appliance unless the ventilation system and appliance have been designed tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination use...

Page 5: ...2 50 mm 2 50 mm 2 50 mm 29 15 16 720 mm NOTE 13 330 mm is the maximum recommended upper cabinet depth Gas line opening Wall everywhere 5 12 7 cm below underside of countertop Cabinet base everywhere...

Page 6: ...to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas...

Page 7: ...closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an...

Page 8: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Page 9: ...CHECK FOR PROPER TIGHTNESS NEVER USE A FLAME Leak testing of the appliance shall be conducted according to the manufacturer s instructions The following procedures must be performed to adjust the gas...

Page 10: ...o secure the hob to the supporting structure adjusting it until perfectly horizontal Carefully trim off the excess edge of the gasket A pic 2 The dimensions in picture 2 below refer to the distance be...

Page 11: ...asket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas connection A before fixing the hob Always place a suitable sealing medium such as Teflon tape between pressure re...

Page 12: ...to the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after top assembly has been completed as and you have checked to ensure that all parts have been fitted pr...

Page 13: ...quipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring e...

Reviews: