Instructions for the Installer

14

5. CHECKING OPERATION

After having fastened the top to the support structure, some simple procedures are required to check for
proper operation.

1)

Check for any gas leaks in the vicinity of the cooktop connector, the pressure regulator and the safety
valve.

WARNING

FIRE HAZARD

-

Use a soapy solution to check for proper tightness.

-

Never test for gas leaks with a match or other flames.

-

Failure to follow this instruction can result in death or fire

NOTE:

The regulator Is fitted with a checkpoint outlet gas pressure to check the exact pressure supplied

to the appliance.

2)

The cooktop's electrical circuit can be checked for proper operation

only after top assembly has been completed as and you have
checked to ensure that all parts have been fitted properly:

1 a spark must light on all burners when the knobs on the top are

pressed

2 when each knob on the cooktop is pressed and turned to the

low flame symbol (

), the entire crown should light.

3 lf burners do not light properly, turn the control knob to the

"OFF" position O . Check that burner caps and crowns are in
the proper position. Check that the power supply cord is
plugged in and that circuit breaker or house fuse has not blown.
Check that the shut-off valve is in the "ON" position. Check
operation again. lf a burner does not light at this point, contact
your dealer for assistance.

Summary of Contents for PGFU30X

Page 1: ...Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions lf you cannot reach your gas supplier call the fire department Installation and service must be perfo...

Page 2: ...nment codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do n...

Page 3: ...Instructions for the Installer 5 2 COOKTOP MEASUREMENTS...

Page 4: ...ir downward toward the appliance unless the ventilation system and appliance have been designed tested in accordance with ANSI Z21 1 and listed by an independent testing laboratory for combination use...

Page 5: ...2 50 mm 2 50 mm 2 50 mm 29 15 16 720 mm NOTE 13 330 mm is the maximum recommended upper cabinet depth Gas line opening Wall everywhere 5 12 7 cm below underside of countertop Cabinet base everywhere...

Page 6: ...to a regular gas supply 1 This installation must conform with all local codes and ordinances In the absence of local codes installation must conform with American National Standard National Fuel Gas...

Page 7: ...closing the respective manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa 6 If the appliance is installed on an...

Page 8: ...SI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances lf a mating outlet is not available it is the personal responsibility and obligation of the...

Page 9: ...CHECK FOR PROPER TIGHTNESS NEVER USE A FLAME Leak testing of the appliance shall be conducted according to the manufacturer s instructions The following procedures must be performed to adjust the gas...

Page 10: ...o secure the hob to the supporting structure adjusting it until perfectly horizontal Carefully trim off the excess edge of the gasket A pic 2 The dimensions in picture 2 below refer to the distance be...

Page 11: ...asket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas connection A before fixing the hob Always place a suitable sealing medium such as Teflon tape between pressure re...

Page 12: ...to the appliance 2 The cooktop s electrical circuit can be checked for proper operation only after top assembly has been completed as and you have checked to ensure that all parts have been fitted pr...

Page 13: ...quipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles WARNING Label all wires prior to disconnection when servicing controls Wiring e...

Reviews: