Instructions for the installer
22
10.3 Burner and nozzle characteristics table
Burner
Rated
heating
capacity
(kW)
LPG – G30/G31
50 mbar
Nozzle
diameter
1/100 mm
Reduced
capacity
(W)
Capacity
g/h G30
Capacity
g/h G31
Auxiliary
1.05
42
400
76
75
Semi-rapid
1.7
54
500
120
118
Medium Rapid
2.6
67
750
189
186
Large Rapid
3.5
76
1050
247
243
Burner
Rated
heating
capacity
(kW)
Natural gas - G20
20 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary
1.05
76
400
Semi-rapid
1.7
95
500
Medium Rapid
2.6
117
750
Large Rapid
3.5
135
1050
Burner
Rated
heating
capacity
(kW)
Natural gas – G25
20 mbar
Nozzle diameter
1/100 mm
Reduced capacity
(W)
Auxiliary
1.05
82
400
Semi-rapid
1.7
105
500
Medium Rapid
2.5
126
750
Large Rapid
3.5
150
1050