Smeg P705VT Instruction Manual Download Page 3

 

 

 

Instructions for the installer 

 

 

20 

2.

 

Positioning of hob 

 

 

 

 

 

The following operation requires building and/or carpentry work so must be carried out 
by a competent tradesman. 

Installation can be carried out on various materials such as masonry, metal, solid 
wood or plastic laminated wood as long as they are heat resistant (T 90°C). 

 

 

2.1

 

Attachment to support structure 

Create an opening with the dimensions shown in the figure in the top surface of the 
counter, keeping a minimum distance of 

50 mm

 from the rear border. This unit may be 

set against walls that are higher than the hob as long as distance “

X

” (see figure) is 

maintained to prevent damage to the walls due to overheating. Make sure there is a 
minimum of 

750 mm

 between the hot plate flames and any shelf that may be installed 

directly above them. In case of installation on a hollow compartment with doors, a 
separating panel has to be placed under the hob. Keep a minimum distance of 

10 mm

 

between the bottom of the unit and the panel surface. The panel has to be easily 
removable to allow access in the event of technical service. 

 

   

  

 

    

 

 

Summary of Contents for P705VT

Page 1: ...__________________________28 5 8 Arrangement of burners on hob ________________________________________28 5 9 Lubrication of gas taps _______________________________________________28 6 Description of...

Page 2: ...ER THE APPLIANCE HAS BEEN BUILT IN NEVER UNPLUG BY PULLING ON THE CABLE IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE COOKING HOB FOLLOWING THE INSTRUCTIONS BELOW SHOULD THE...

Page 3: ...the counter keeping a minimum distance of 50 mm from the rear border This unit may be set against walls that are higher than the hob as long as distance X see figure is maintained to prevent damage t...

Page 4: ...e onto the glass surface to separate it from the unit After fixing the provided adhesive sponge B to the glass mount the device to the unit with the mounting brackets A provided with the device itself...

Page 5: ...to 3 mm located in an easily accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced the wire section on the new cable must not be less than 0 75 mm2 3...

Page 6: ...t a pressure of 20 mbar For use with other types of gases see Section 5 Adapting to different types of gas The gas intake fitting is gas external threaded ISO 228 1 Connection with rigid copper pipe P...

Page 7: ...intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid...

Page 8: ...nd regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob Remove all of the burner components by following the numerical sequence shown in the fig...

Page 9: ...dium rapid 2 3 75 40 43 700 167 164 Large rapid 3 0 82 40 45 800 218 215 A 76 UR B 3 6 48 48 52 1000 261 257 diameters marked and must be fitted respectively on valves marked and shown inpoint 5 6 Reg...

Page 10: ...ir is set correctly 5 5 Reassembling the hob Follow the instructions given in paragraph 5 1 Removing the hob but in the reverse order When replacing the burner rings remember that they have to be tigh...

Page 11: ...el is inside the bag that contains the nozzles 5 8 Arrangement of burners on hob BURNERS 1 Auxiliary 2 Semi rapid 3 Medium rapid 4 Large rapid 5 UR If the flame of the UR burners have unstable flame t...

Page 12: ...EL 100 CONTROL PANEL DESCRIPTION OF THE KNOB The flame is lit by pressing the knob and simultaneously turning it anticlockwise to the minimum flame symbol To adjust the flame turn the knob to the zone...

Page 13: ...device It may happen that the burner goes out when the knob is released In this case repeat the operation keeping the knob pressed down for a longer time If the burners should go out accidentally afte...

Page 14: ...aps In normal use of the hob the grids and burner caps normally get browned as a result of the high temperature For optimum cleaning remove the burner cap and lift up one of the horizontal spokes of t...