Activated charcoal filter (Recirculation version)
REPLACING THE ACTIVATED CHARCOAL FILTER
• The filter is not washable and cannot be
regenerated. It must be replaced when led S1
flashes twice or at least every 4 months. The
alarm signal will only light up when the extractor
motor is switched on.
Alarm signal reset
• Switch off the lights and extractor motor.
• Press button V2 for at least 3 seconds, until the
leds start to flash.
Replacing the Filter
• Remove the metal grease filters.
• Remove the saturated activated carbon filter by
releasing the fixing hooks.
• Fit the new filter by hooking it into its seating
Replace the metal grease filters.
Alarm signal activation
• On the recirulcation version extractor hood, the
filter saturation alarm is activated during
installation or at a later date.
• Switch off the lights and extractor motor.
• Press button V2 for at least 10 seconds, until
the leds start to flash:
• 2 flashes of the activated carbon odour filter
saturation alarm led = filter ACTIVATED
• 1 flash of the activated carbon odour filter
saturation alarm led = filter DEACTIVATED
Lighting
LIGHT REPLACEMENT
20 W halogen light.
• Remove the 2 screws fixing the Lighting support,
and pull it out of from the Hood.
• Extract the lamp from the Support.
• Replace with another of the same type, making
sure that the two pins are properly inserted in
the lamp holder socket holes.
• Replace the Support and fix it in place with the