Smeg KSE920X Instruction Manual Download Page 11

EN

2

27

Activated Charcoal Filter (Recirculation Version) 

This cannot be washed or regenerated, and must be changed when 

G

 starts to flash, or at least 

once every 4 months. The Alarm signal, if it has been activated, only appears when the Suction 
motor is turned on.

Activating the alarm signal  

• In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on 

installation or at a later date. 

•  Turn the Lights and the Suction Motor off. 
• Press 

F

and hold for approximately 5 seconds: 

Button B

flashes twice -- A.C. Filter saturation alarm 

ACTIVATED

Button B

flashes once -- A.C. Filter saturation alarm 

DEACTIVATED

CHANGING THE ACTIVATED CHARCOAL FILTER 

Resetting the alarm signal 

•  Turn the Lights and the Suction Motor off. 
• Press button 

G

 and hold for approximately 5 seconds (See 

paragraph on Use). 

Changing the Filter 

•  Remove the metal grease filters. 
•  Remove the saturated charcoal filter by releasing the fixing 

hooks

•  Fit the new filter and fasten it in its correct position. 
•  Put the metal grease filters in their seats. 

Lighting 

LIGHT REPLACEMENT 

20 W halogen light. 

•  Remove the snap-on lamp cover by levering it from under the 

metal ring, supporting it with one hand. 

•  Remove the halogen lamp from the lamp holder by pulling 

gently. 

•  Replace the lamp with a new one of the same type, making 

sure that you insert the two pins properly into the housings on 
the lamp holder. 

•  Replace the snap-on lamp cover.

Summary of Contents for KSE920X

Page 1: ...Libretto di Istruzioni Manuel d Instructions Instructions Manual Gebruiksaanwijzing Bedienungsanleitung Bruksanvisning Manual de instrucciones Manual de Instru es Brugsvejledning KSE920X...

Page 2: ...COMMENDATIONS AND SUGGESTIONS 20 CHARACTERISTICS 21 INSTALLATION 22 USE 25 MAINTENANCE 26 INHOUDSOPGAVE ADVIEZEN EN SUGGESTIES 28 EIGENSCHAPPEN 29 INSTALLATIE 30 GEBRUIK 33 ONDERHOUD 34 INHALTSVERZEIC...

Page 3: ...53 INSTALACI N 54 USO 57 MANTENIMIENTO 58 NDICE CONSELHOS E SUGEST ES 60 CARACTER STICAS 61 INSTALA O 62 UTILIZA O 65 MANUTEN O 66 68 69 70 73 74 INDHOLD R D OG ANVISNINGER 76 APPARATBESKRIVELSE 77 IN...

Page 4: ...er to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Neve...

Page 5: ...n 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 10 1 Damper 150 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fix...

Page 6: ...w the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as i...

Page 7: ...up plied To install a 120 pipe To install a 120 mm air exhaust connection insert the redu cer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any a...

Page 8: ...n the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure...

Page 9: ...speed one and allows recirculation for 10 minutes every hour It cannot be activated if the Intensive or Delay functions are in use On Off When the filters alarm is triggered the alarm can be reset by...

Page 10: ...ntly if use is particularly intensive Resetting the alarm signal Turn the Lights and the Suction motor off then disable the 24h function if enabled Press button G and hold for approximately 5 seconds...

Page 11: ...larm DEACTIVATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Turn the Lights and the Suction Motor off Press button G and hold for approximately 5 seconds See paragraph on Use Ch...

Reviews: