LIGHT REPLACEMENT 

20 W halogen light. 

•  Remove the snap-on lamp cover by levering it from 

under the metal ring, supporting it with one hand. 

•  Remove the halogen lamp from the lamp holder by 

pulling gently. 

•  Replace the lamp with a new one of the same type, 

making sure that you insert the two pins properly into 
the housings on the lamp holder. 

•  Replace the snap-on lamp cover.

 

 

 

 

 
 

Lamp 

Power (W) 

Socket 

Voltage (V) 

Dimension (mm) 

ILCOS Code 

 

28 

E14 

220 – 240 

104 x 35 

HSGSB/C/UB-28-220/240-E14 

 

28 E14 230  85x25  HDG-28-230-E14-25 

 

20 G4 12  33 

9 HSG/C/UB-20-12-G4 

35 

GU10 

230 

51 x 50,7 

HAGS-35-230-GU10-51/40 

 

50 

GU10 

230 

51 x 50,7 

HAGS-35-230-GU10-51/20 

20 

GU4 

12 

40 x 35 

HRGS-20-12-GU4-35/30 

 

20 

GU5.3 

12 

46 x 51 

HRGS-20-12-GU5.3-50/10 

16 

G13 

95 

720 x 26 

FD-16/40/1B-E-G13-26/720 

 

18 

G13 

57 

589,8 x 26 

FD-18/40/1B-E-G13-26/600 

9 G23 

60 (lamp) 

220-240 (starter) 

167 x 28 

FSD-9/27/1B-I-G23 

 

11 G23 

91 (lamp) 

220-240 (starter) 

235,8 x 28 

FSD-11/40/1B-I-G23 

Summary of Contents for KFV62DBE

Page 1: ...ual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Brugsvejledning Bruksanvisning Instrukcja Obs ugi Bruksanvisning K ytt ohje KFV62DE KFV62DN...

Page 2: ...E CONSEILS ET SUGGESTIONS 25 CARACTERISTIQUES 28 INSTALLATION 29 UTILISATION 32 ENTRETIEN 33 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 35 CHARAKTERISTIKEN 38 MONTAGE 39 BEDIENUNG 42 WARTUNG 43 INHO...

Page 3: ...8 INSTALLATION 89 ANV NDING 92 UNDERH LL 93 INDHOLD R D OG ANVISNINGER 95 APPARATBESKRIVELSE 98 INSTALLATION 99 BRUG 102 VEDLIGEHOLDELSE 103 SPIS TRE CI UWAGI I SUGESTIE 105 W A CIWO CI TECHNICZNE 108...

Page 4: ...4 4 SIS LT OHJEET JA SUOSITUKSET 125 MITAT JA OSAT 128 ASENNUS 129 K YTT 132 HUOLTO 133 135 138 139 142 143 FI SA...

Page 5: ...lue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical applian...

Page 6: ...y to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flamb...

Page 7: ...eavy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indica...

Page 8: ...wer Section 9 1 Reducer Flange 150 120 mm 10 1 Damper 150 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Bracke...

Page 9: ...the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as in...

Page 10: ...up plied To install a 120 pipe To install a 120 mm air exhaust connection insert the re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any a...

Page 11: ...the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure th...

Page 12: ...on and off at low speed Used to provide a continuous and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating conditions given the optimum trea...

Page 13: ...o bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CH...

Page 14: ...on lamp cover Lamp Power W Socket Voltage V Dimension mm ILCOS Code 28 E14 220 240 104 x 35 HSGSB C UB 28 220 240 E14 28 E14 230 85x25 HDG 28 230 E14 25 20 G4 12 33 x 9 HSG C UB 20 12 G4 35 GU10 230...

Reviews: