Smeg KFV62DBE Instruction Manual Download Page 10

 

 

 

 

EN 

2

20 

Mounting the hood body 

•  Before attaching the hood body, tighten the two screws 

Vr

 lo-

cated on the hood body mounting points. 

•  Hook the hood body onto the screws 

12a

•  Fully tighten the support screws 

12a

•  Adjust the screws 

Vr

 to level the hood body. 

 

12a

Vr

 

Connections 

DUCTED VERSION AIR EXHAUST SYSTEM 

When installing the ducted version, connect the hood to the 
chimney using either a flexible or rigid pipe ø 150 or 120mm, the 
choice of which is left to the installer. 

To install a ø 150 pipe 

•  To install the dumper 

10

 

•  Fix the pipe in position using sufficient pipe clamps (not sup-

plied). 

To install a ø 120 pipe 

•  To install a ø 120 mm air exhaust connection, insert the re-

ducer flange 

9

 on the dumper 

10

•  Fix the pipe in position using sufficient pipe clamps (not sup-

plied). 

•  Remove any activated charcoal filters. 

 

9

ø 120

ø 150

10

10

RECIRCULATION VERSION AIR OUTLET 

•  Insert the connection extension pieces laterally 

14.1

 in connec-

tion 

15.

 

•  Insert the Connector 

15

 into the Support bracket 

7.3

 and fix it 

with a screw. 

•  Make sure that the outlet of the extension pieces 

14.1

 is hori-

zontally and vertically aligned with the chimney outlets.  

•  Connect the air outlet connection 

15

 to the hood body outlet 

using either a flexible or rigid pipe   ø 150 mm, the choice of 
which is left to the installer. 

•  Ensure that the activated charcoal filters have been inserted. 

 

ø 150

15

14.1

7.3

Summary of Contents for KFV62DBE

Page 1: ...ual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Brugsvejledning Bruksanvisning Instrukcja Obs ugi Bruksanvisning K ytt ohje KFV62DE KFV62DN...

Page 2: ...E CONSEILS ET SUGGESTIONS 25 CARACTERISTIQUES 28 INSTALLATION 29 UTILISATION 32 ENTRETIEN 33 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 35 CHARAKTERISTIKEN 38 MONTAGE 39 BEDIENUNG 42 WARTUNG 43 INHO...

Page 3: ...8 INSTALLATION 89 ANV NDING 92 UNDERH LL 93 INDHOLD R D OG ANVISNINGER 95 APPARATBESKRIVELSE 98 INSTALLATION 99 BRUG 102 VEDLIGEHOLDELSE 103 SPIS TRE CI UWAGI I SUGESTIE 105 W A CIWO CI TECHNICZNE 108...

Page 4: ...4 4 SIS LT OHJEET JA SUOSITUKSET 125 MITAT JA OSAT 128 ASENNUS 129 K YTT 132 HUOLTO 133 135 138 139 142 143 FI SA...

Page 5: ...lue must be as short as possible Do not connect the extractor hood to exhaust ducts carrying combustion fumes boilers fireplaces etc If the extractor is used in conjunction with non electrical applian...

Page 6: ...y to direct it onto the bottom of the pan only making sure that it does not engulf the sides Deep fat fryers must be continuously monitored during use overheated oil can burst into flames Do not flamb...

Page 7: ...eavy usage Failure to carry out cleaning as indicated will result in a fire hazard Clean the hood using a damp cloth and a neutral liquid detergent The symbol on the product or on its packaging indica...

Page 8: ...wer Section 9 1 Reducer Flange 150 120 mm 10 1 Damper 150 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Installation Components 7 2 1 2 Upper Chimney Section Fixing Bracke...

Page 9: ...the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket Mark a reference point as in...

Page 10: ...up plied To install a 120 pipe To install a 120 mm air exhaust connection insert the re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not sup plied Remove any a...

Page 11: ...the two sides of the upper flue and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets by using the 4 screws 12c 2 9 x 9 5 supplied Make sure th...

Page 12: ...on and off at low speed Used to provide a continuous and silent air change in the presence of light cooking vapours V2 Speed Medium speed suitable for most operating conditions given the optimum trea...

Page 13: ...o bend them Allow them to dry before refitting When refitting the filters make sure that the handle is visible on the outside Activated charcoal filter Recirculation version REPLACING THE ACTIVATED CH...

Page 14: ...on lamp cover Lamp Power W Socket Voltage V Dimension mm ILCOS Code 28 E14 220 240 104 x 35 HSGSB C UB 28 220 240 E14 28 E14 230 85x25 HDG 28 230 E14 25 20 G4 12 33 x 9 HSG C UB 20 12 G4 35 GU10 230...

Reviews: