Smeg KAT700HXE Instruction On Mounting And Use Manual Download Page 9

 

13 

Additional Installation Specifications:  

Use only the fixing screws supplied with the product for installation 
or, if not supplied, purchase the correct screws type. 
Use the correct length for the screws which are identified in the 
Installation Guide. 
In case of doubt, consult an authorised service assistance centre 
or similar qualified person.  

WARNING! 

Failure to install the screws or fixing device in 

accordance with these instructions may result in electrical hazards. 

 

Use 

The hood is designed to be used either for exhausting or filter 
version. 
  

 Ducting version

 

In this case the fumes are conveyed outside of the building by 
means of a special pipe connected with the connection ring 
located on top of the hood. 

Attention

! The exhausting pipe is not supplied and must be 

purchased apart. 
Diameter of the exhausting pipe must be equal to that of the 
connection ring. 
In the horizontal runs the exhausting pipe must be slightly 
slanted (about 10°) and directed upwards to vent the air easily 
from the room to the outside. 
Attention! If the hood is supplied with active charcoal filter, 
then it must be removed. 

Connect the hood and discharge holes on the walls with a 
diameter equivalent to the air outlet (connection flange). 
Using the tubes and discharge holes on walls with smaller 
dimensions will cause a diminution of the suction performance 
and a drastic increase in noise. 

Any responsibility in the matter is therefore declined.  

Use a duct of the minimum indispensible length. 

Use a duct with as few elbows as possible (maximum 
elbow angle: 90°). 

Avoid drastic changes in the duct cross-section. 

Use a duct as smooth as possible inside. 

The duct must be made of certified material. 

  

 Filter version

 

One active charcoal filter is needed for this and can be 
obtained from your usual retailer.  
The filter removes the grease and smells from the extracted 
air before sending it back into the room through the upper 
outlet grid. 
  
The models with no suction motor only operate in ducting 
mode, and must be connected to an external suction device 
(not supplied). 
The connecting instructions are supplied with the peripheral 
suction unit.  

 

Installation 

The minimum distance between the supporting surface for the 
cooking equipment on the hob and the lowest part of the 
range hood must be not less than 50cm from electric cookers 
and 65cm from gas or mixed cookers. 
If the instructions for installation for the gas hob specify a 
greater distance, this must be adhered to. 
  

 

  Electrical connection 

The mains power supply must correspond to the rating indicated 
on the plate situated inside the hood. If provided with a plug 
connect the hood to a socket in compliance with current 
regulations and positioned in an accessible area, after installation. 
If it not fitted with a plug (direct mains connection) or if the plug is 
not located in an accessible area, after installation,  apply a double 
pole switch in accordance with standards which assures the 
complete disconnection of the mains under conditions relating to 
over-current category III, in accordance with installation 
instructions. 

Warning!

 Before re-connecting the hood circuit to the mains 

supply and checking the efficient function, always check that the 
mains cable is correctly assembled. 
The hood is provided with a special power cable ; if the cable is 
damaged, request a new one from Technical Service. 

 

Mounting 

Before beginning installation: 

 

• 

Check that the product purchased is of a suitable size for the 
chosen installation area. 

• 

Remove the charcoal (*) filter/s if supplied (see also relative 
paragraph). This/these is/are to be mounted only if you want 
lo use the hood in the filtering version. 

• 

Check (for transport reasons) that there is no other supplied 
material inside the hood (e.g. packets with screws (*), 
guarantees (*), etc.), eventually removing them and keeping 
them. 

•  If possible, disconnect and move freestanding or slide-in 

range from cabinet opening to provide easier access to rear 
wall/ceiling. Otherwise put a thick, protective covering over 
countertop, cooktop or range to protect from damage and 
debris. Select a flat surface for assembling the unit. Cover 
that surface with a protective covering and place all canopy 
hood parts and hardware in it. 

•  In addition check whether near the installation area of the 

hood (in the area accessible also with the hood mounted) an 
electric socket is available and it is possible to connect a 
fumes discharge device to the outside (only suction version).  

• 

Carry out all the masonry work necessary (e.g. installation of 
an electric socket and/or a hole for the passage of the 
discharge tube). 

Expansion wall plugs are provided to secure the hood to most 
types of walls/ceilings. However, a qualified technician must verify 
suitability of the materials in accordance with the type of 
wall/ceiling. The wall/ceiling must be strong enough to take the 
weight of the hood. 

Do not tile, grout or silicone this appliance 

to the wall. Surface mounting only. 