Smeg KAT700HXE Instruction On Mounting And Use Manual Download Page 10

 

14 

  

 

Operation 

Use the high suction speed in cases of concentrated kitchen 
vapours.  It is recommended that the cooker hood suction is 
switched on for 5 minutes prior to cooking and to leave in 
operation during cooking and for another 15 minutes 
approximately after terminating cooking.  
  

 

  

1. Lights 

ON/OFF 

2. Motor 

ON/OFF 

 When 

key 

“2”

 is pressed the motor passes to speed 1. 

 

If the key is pressed during working, the hood passes to 

OFF 

state. 

3. Speed 

decrease 

 When 

key 

“3”

 is pressed the speed decreases from 4 

(intense) to 1. 

4. Speed 

increase 

 When 

key 

“4”

 is pressed with the hood in 

OFF 

state, the 

hood passes to speed 1. 

 

If the key is pressed during working, the speed increases 
from 1 to 4 (intense). 

 

The intense speed is timed. The standard timing is 5’, at 
the end of which the hood sets at speed 2. 

 

To deactivate the function before the end of the time, 
press key 

“3”

, the hood sets at speed 3, when key 

“2”

 is 

pressed the hood turns off. 

 

A signal on the display corresponds to each speed: 

 

OFF: No signal 

 Speed 

1: 

1

 

 Speed 

2: 

2

 

 Speed 

3: 

3

 

 Speed 

4: 

4

 flashing 

5. Display 

 

Grease filter signalling 

The grease filter is signalled by the display with number 1 
flashing after 40 hours of use. 
This means that the grease filter needs to be washed. 
The signalling is visible with the hood in 

ON 

state. 

To eliminate the grease filter signalling, press key 

“2”

 for 

more than 3”, until it turns off. 
The signalling can be eliminated with the hood in 

ON

 state. 

 

Carbon filter signalling (only for filtering version) 

The carbon filter is signalled by the display with number 2 
flashing after 160 hours of use. 
This means that the carbon filter installed must be replaced. 
The signalling is visible with the hood in 

ON 

state. 

To eliminate the carbon filter signalling, press key 

“2”

 for 

more than 3”, until it turns off. 

The signalling can be eliminated with the hood in 

ON

 state. 

 
In case both filters are signalled at the same time, numbers 1 
and 2 flash on the display alternately. 
The signalling can be reset by carrying out the above-
described procedure twice. 
First it resets the grease filter signalling, then the carbon filter 
signalling. 
 
In the standard mode the carbon filter signalling is not active. 
In case the filtering version hood is used, it is necessary to 
enable the carbon filter signalling. 
 

Activation of carbon filter signalling: 

Set the hood to 

OFF

 and keep keys 

“2”

 and 

“3”

 pressed 

contemporaneously for 3”. 
Numbers 1 and 2 flash alternately for 2”. 

Deactivation of carbon filter signalling: 

Set the hood to 

OFF

 and keep keys 

“2”

 and 

“3”

 pressed 

contemporaneously for 3”. 
Number 1 flashes for 2”. 
 

Temperature Alarm 

The hood is equipped with a temperature sensor which 
activates the motor at speed 3 in case the temperature in the 
display zone is too high. 
The alarm condition is indicated by the display with the letter 

t

 

flashing. 
This condition remains as such until the temperature falls 
below the alarm threshold. 
This mode can be quit by pressing key 

“2”

“3”

 or 

“4”

Every 30” the sensor checks the ambient temperature of the 
display zone. 
  