ELECTRICAL CONNECTION 

•  Connect the hood to the mains through a two-pole switch hav-

ing a contact gap of at least 3 mm. 

•  Remove the grease filters (see paragraph Maintenance) being 

sure that the connector of the feeding cable is correctly inserted 
in the socket placed on the side of the fan. 

Chimney assembly 

Upper exhaust Chimney 
•  Slightly widen the two sides of the upper chimney and hook 

them behind the brackets 7.2.1, making sure that they are well 
seated. 

•  Secure the sides to the brackets using the 4 screws 12c (2,9 x 

9,5) supplied. 

Lower exhaust Chimney 
•  Slightly widen the two sides of the chimney and hook them 

between the upper chimney and the wall, making sure that they 
are well seated. 

•  Fix the lower part laterally to the hood body using the 2 screws 

12c (2,9 x 9,5) supplied. 

12c

2.1

2.2

2

7.2.1

12c

Summary of Contents for K90X

Page 1: ...Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Bruksanvisning K90X...

Page 2: ...CONSEILS ET SUGGESTIONS 20 CARACTERISTIQUES 21 INSTALLATION 22 UTILISATION 25 ENTRETIEN 26 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 28 CHARAKTERISTIKEN 29 MONTAGE 30 BEDIENUNG 33 WARTUNG 34 INHOU...

Page 3: ...DICE CONSELHOS E SUGEST ES 52 CARACTER STICAS 53 INSTALA O 54 UTILIZA O 57 MANUTEN O 58 60 61 62 65 66 INNEH LL REKOMMENDATIONER OCH TIPS 68 EGENSKAPER 69 INSTALLATION 70 ANV NDING 73 UNDERH LL 74 PT...

Page 4: ...er than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it...

Page 5: ...s 2 1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 10 1 Damper 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Install...

Page 6: ...wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket...

Page 7: ...ent pipe clamps not sup plied To install a 120 pipe To install a 120 mm air exhaust connection insert the re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not s...

Page 8: ...assembly Upper exhaust Chimney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using t...

Page 9: ...cooking fumes it is de activated by pressing any one of the Speed buttons T1 T2 T3 It cannot be activated if the Delay function is in use If the filter saturation alarm is on this resets it On Flashi...

Page 10: ...od canopy and close it by turning the knob in the opposite direction Metal grease filters These can also be washed in the dishwasher and need to be cleaned when all the command LEDs light up in a cont...

Page 11: ...turation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press any of the buttons except the Light button Changing the Filter Open the comfort panel Remove the Met...