Activated Charcoal Filter (Recirculation Version) 

•  This cannot be washed or regenerated, and must be changed when all the command LEDs 

start to flash, or at least once every 4 months.  

Activating the alarm signal 
•  In Recirculation Version Hoods, the Filter Saturation Alarm must be activated on installation or at 

a later date. 

•  Press and hold the Delay button (T4) on the keypad for 5 seconds and the following will be dis-

played: 

  •  Leds (L1-L2-L3) flash twice – Activated Charcoal Filter saturation alarm ACTIVATED. 
  •  Leds (L1-L2-L3) flash once – Activated Charcoal Filter saturation alarm DEACTI

 VATED. 

CHANGING THE ACTIVATED CHARCOAL FILTER

Resetting the alarm signal
•  Press any of the buttons except the Light button. 

Changing the Filter
•  Open the comfort panel. 
•  Remove the Metal grease filters. 
•  Remove the saturated Activated Charcoal filter, as shown in 

the figure. 

•  Fit the new Filter, hooking it into place. 
•  Replace the Metal grease filters. 
•  Close the comfort panel. 

Lighting

LIGHT REPLACEMENT 

20 W halogen light. 
•  Remove the snap-on lamp cover by levering it from under the 

metal ring, supporting it with one hand. 

•  Remove the halogen lamp from the lamp holder by pulling 

gently. 

•  Replace the lamp with a new one of the same type, making 

sure that you insert the two pins properly into the housings on 
the lamp holder. 

•  Replace the snap-on lamp cover.

Summary of Contents for K90X

Page 1: ...Libretto di Istruzioni Instructions Manual Manuel d Instructions Bedienungsanleitung Gebruiksaanwijzing Manual de instrucciones Manual de Instru es Bruksanvisning K90X...

Page 2: ...CONSEILS ET SUGGESTIONS 20 CARACTERISTIQUES 21 INSTALLATION 22 UTILISATION 25 ENTRETIEN 26 INHALTSVERZEICHNIS EMPFEHLUNGEN UND HINWEISE 28 CHARAKTERISTIKEN 29 MONTAGE 30 BEDIENUNG 33 WARTUNG 34 INHOU...

Page 3: ...DICE CONSELHOS E SUGEST ES 52 CARACTER STICAS 53 INSTALA O 54 UTILIZA O 57 MANUTEN O 58 60 61 62 65 66 INNEH LL REKOMMENDATIONER OCH TIPS 68 EGENSKAPER 69 INSTALLATION 70 ANV NDING 73 UNDERH LL 74 PT...

Page 4: ...er than for which it has been designed Never leave high naked flames under the hood when it is in operation Adjust the flame intensity to direct it onto the bottom of the pan only making sure that it...

Page 5: ...s 2 1 Telescopic Chimney comprising 2 1 1 Upper Section 2 2 1 Lower Section 9 1 Reducer Flange 150 120 mm 10 1 Damper 14 1 2 Air Outlet Connection Extension 15 1 Air Outlet Connection Ref Q ty Install...

Page 6: ...wall as shown at X mm below the first bracket X height of the upper chimney section supplied aligning the centre notch with the vertical line Mark the wall at the centres of the holes in the bracket...

Page 7: ...ent pipe clamps not sup plied To install a 120 pipe To install a 120 mm air exhaust connection insert the re ducer flange 9 on the dumper 10 Fix the pipe in position using sufficient pipe clamps not s...

Page 8: ...assembly Upper exhaust Chimney Slightly widen the two sides of the upper chimney and hook them behind the brackets 7 2 1 making sure that they are well seated Secure the sides to the brackets using t...

Page 9: ...cooking fumes it is de activated by pressing any one of the Speed buttons T1 T2 T3 It cannot be activated if the Delay function is in use If the filter saturation alarm is on this resets it On Flashi...

Page 10: ...od canopy and close it by turning the knob in the opposite direction Metal grease filters These can also be washed in the dishwasher and need to be cleaned when all the command LEDs light up in a cont...

Page 11: ...turation alarm DEACTI VATED CHANGING THE ACTIVATED CHARCOAL FILTER Resetting the alarm signal Press any of the buttons except the Light button Changing the Filter Open the comfort panel Remove the Met...

Reviews: