![Smeg GW-L227 Service Manual Download Page 35](http://html1.mh-extra.com/html/smeg/gw-l227/gw-l227_service-manual_1303940035.webp)
TROUBLE DIAGNOSIS
No
Yes
In Crush Mode,
Is the voltage between
pin1 and pin5 of CON5
like as below, while
pushing the lever switch?
230 V
pin1 To pin5
Pushing
Normal
Level switch
0 ~ 2V
pin1 To pin5
Result
Test Point
Pin1
Replace
Main PCB
No
Yes
12.3 ~ 15.1
Ω
(1) To (2)
Result
Test Point
Is the resistance value
between (1) and (2) of the
Auger motor like as below?
Replace
Auger Motor
(1)(2)
No
Yes
Is the resistance between
(1) and (2) of the
Dispenser solenoid like as
below?
283 ~328
Ω
(1) To (2)
Result
Test Point
Resistance of Dispenser solenoid
Replace
Dispenser
Solenoid
(1)
(2)
No
Yes
Is the condition of
the micro switch like as
below?
Replace
Micro
Switch
After plug in,
explain to the customer!
Infinity
Normal
0
Ω
Push the Lever
Tester
Status
(1)
(2)
Output voltage of dispenser solenoid
Pin5