Instructions for the installer
27
5. INSTALLING THE APPLIANCE
The appliance must be installed by a qualified technician and according to the regulations in force.
This appliance may be installed next to a wall which is higher than the appliance, with a minimum
distance of 5 cm from the side of the appliance, as shown in drawings A and B showing the correct
installation conditions. Any wall cupboards or shelves must be at a distance of at least 75 cm above the
work surface.
A)
B)
Built-in appliance
Free-standing appliance
5.1 Electrical connection
Make sure the voltage and the cross-section of the power cord match the specifications indicated on the
rating plate positioned in the storage compartment.
Do not remove this plate for any reason.
If the appliance is connected to the power supply network by means of a fixed connection, install a
multipolar cut-out device on the power supply line, in compliance with installation regulations, located
near the appliance and in an easily reachable position.
Connection to the supply may be fixed or with plug and socket. In the latter case the plug and socket
must be suitable for the cable employed and conform to the regulations in force. Regardless of the type
of connection, the appliance must be earthed. Before connection, make sure that the power supply line
is suitably earthed. Avoid the use of reducers, adapters or shunts which may cause overheating.
For operation on
380-415V 3N~
: use an H05V2V2-F type five-core cable (5
x 4 mm
2
).
For operation on
380-415V 2N~
: use an H05V2V2-F type four-core cable (4
x 6 mm
2
).
Operation at
220-240V~:
use a 3 x 10mm² three-core cable:
This type of connection is permitted solely using the special kit available at
Service Centres (part. no.
KITMT code 902263
)
The earth wire (yellow-green) must be at least 20 mm longer than the other
wires at the end for connection to the appliance.
750
mm
50
mm
50
mm
750
mm
220-240V~
10 mm
2
20 mm