background image

Instructions for the installer

37

14.INSTALLATION OF THE APPLIANCE

It is the law that all gas appliances are installed by 

competent persons

. Corgi gas installers are

approved to work to safe and satisfactory standards. All gas installation, servicing and repair work must
be in accordance with the gas safety regulations 1984 (installation and use) as amended 1990.
This appliance may be installed next to a wall which is higher than the appliance, as shown in the
diagram

 

showing the correct installation conditions. Any wall cupboards or shelves must be at a distance

of at least 750 m above the work surface.

14.1 Electrical connection

The I.D. plate with techinical data, registration number and brand name is visibily positioned in the
storage compartment.

The plate must not be removed

.

If the appliance is connected to the supply by means of a fixed connection, install a multipolar cut-out
device on the line, with contact opening distance equal to or greater than 

3 mm

, located near the

appliance and in an easily reachable position.

Connection to the supply may be fixed or with plug and socket. In the latter case the plug and socket
must be suitable for the cable employed and conform with the regulations in force. Regardless of the
type of connection, earthing of the appliance is absolutely obligatory. Before connection make sure that
the supply line is suitably earthed. Avoid the use of reducers, adapters or shunts.

For operation on 220-240V~:

 use a three-pole H05RR-F cable

having a cross section of 3 x 1.5 mm

2

The cable end to be connected to the appliance must be provided
with ground wire (yellow-green) at least 20 mm longe.

The manufacturer declines all responsibility 

for damage to persons or things caused by non-

observance of the above prescriptions.

14.2 Ventilation requirements

The room containing the appliance should have an air supply in accordance with B.S. 5440 part 2 1989.
3 All rooms require an opening window or equivalent, and some rooms will require a permanent vent as

well.

4 For room volumes up to 5 m

3

 an air vent of 100 cm

2

 is required.

5 If the room has a door that opens directly to the outside, and the room exceeds 1 m

3

 no air vent is

required.

6 For room volumes between 5 m

3

 and 10 m

3

 an air vent of 50 cm

2

 is required.

7 If there are other fuel burning appliances in the same room B.S. 5440 part 2 1989 should be

consulted to determine the air vent requirements.

8 This appliance must not be installed in a bed sitting room of less than 20 m

3

 or in a bathroom or

shower room.

Windows and permanent vents should therefore not be blocked or removed without first consulting a
Corgi gas installer.

Failure to install appliances correctly is dangerous and could lead to prosecution.

Summary of Contents for CX81VMTT

Page 1: ...ven 35 12 6 Door glass 35 12 7 Routine cleaning of the toaster 35 13 EXTRAORDINARY MAINTENANCE 36 13 1 Lubrication of the taps 36 13 2 Replacement of light bulb 36 13 3 Removing the door 36 13 4 Oven...

Page 2: ...ARP SCRAPERS THEY WILL DAMAGE THE SURFACE USE NORMAL NON ABRASIVE PRODUCTS FOR STEEL AND A WOODEN OR PLASTIC TOOL IF NECESSARY RINSE THOROUGHLY AND DRY WITH A SOFT CLOTH OR DEERSKIN DO NOT ALLOW RESID...

Page 3: ...L ASSISTANCE CENTRE NEVER ATTEMPT TO REPAIR THE APPLIANCE DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS ON THE HOB GRIDS DO NOT USE CONTAINERS OR BROILERS THAT EXTEND BEYOND THE OUTER PERI...

Page 4: ...OASTER COMPARTMENT STORAGE COMPARTMENT Do not leave the packing in the home environment separate the various waste materials and take them to the nearest special garbage collection centre The inside o...

Page 5: ...peat the operation holding down the knob a little longer This operation is not necessary for burners without thermocouples For models with thermocouples should the burner accidentally go out a safety...

Page 6: ...of the timer knob refer to point 11 TIMER HOB BURNER COMMAND KNOB The flame is lit by pressing the knob and turning it anticlockwise to minimum flame To adjust the flame turn the knob between maximum...

Page 7: ...EMENT VENTILATION GRILL ELEMENT VENTILATED HEATING ELEMENT VENTILATION TIMER KNOB This knob allows timed cooking procedures to be carried out using both the electric oven and the toaster For informati...

Page 8: ...always leave the door open as short a time as possible to prevent the temperature in the oven from falling and ruining the food 9 2 Use of the electric grill For short cooking procedures such as the f...

Page 9: ...amage the enamel coating If you wish to use greaseproof paper place it so that it will not interfere with the hot air circulation inside the oven When using the oven remove all unused baking sheets an...

Page 10: ...t over the pins 2 6 After installation the toaster must be in the position shown on the right 3 To remove the toaster reverse the order of the operations just described 10 2 Selecting a function There...

Page 11: ...cooking can be set The cooking time must never be longer than 5 minutes if the toaster is cold for subsequent toasting operations the time can be reduced to as little as 2 minutes and 30 seconds Natur...

Page 12: ...a cloth before opening it To replace the lid fit it into the guides and screw in the hinge fixing screws with the lid open Take care not to touch the glass of the lid with hot pots and pans The glass...

Page 13: ...should always be kept clean Use absorbent kitchen paper to clean In case of tough spots clean with a damp sponge using regular detergent 12 7 Routine cleaning of the toaster Routine cleaning of the to...

Page 14: ...with another similar bulb 25 W Refit the cover A Only use oven bulbs T 300 C 13 3 Removing the door Hold the door on both sides with both hands near hinges A and raise levers B Lift up the door formi...

Page 15: ...earthing of the appliance is absolutely obligatory Before connection make sure that the supply line is suitably earthed Avoid the use of reducers adapters or shunts For operation on 220 240V use a th...

Page 16: ...ordance to B S 669 The hose connection at the rear of the appliance has a BSP internal thread Please use seal C between the flexible connection L and the appliance supply tube B When making the connec...

Page 17: ...as the burner nozzles must be changed and the minimum flame adjusted on the gas taps To change the nozzles proceed as described below 15 1 Replacement of nozzles on the hob 1 Extract the grids and rem...

Page 18: ...50 30 350 72 71 Semi rapid 1 75 65 33 450 127 125 Rapid 2 5 79 45 800 181 178 Triple crown 3 5 94 65 1500 254 250 Burner Rated heating capacity kW NATURAL GAS G20 20 mbar Nozzle diameter 1 100 mm Red...