‐
CW
420/430
19
6.7
Autostart
function
Modify
the
parameter
(ON/OFF)
by
pressing
.
Set
at
“on”
to
start
the
cycle
when
the
door
is
closed.
Set
at
“off”
for
cycle
start
after
confirmation
with
the
start
button
6.8
Regeneration
frequency
setup
(models
with
softener)
(Default
value:
H03
;
modify
the
parameter
to
suit
the
mains
water
hardness.
At
first
use,
the
salt
tank
has
to
be
filled.
It
is
subsequently
sufficient
simply
to
fill
up
with
regenerating
salt
when
necessary.
Modify
the
value
of
the
parameter
by
pressing
.
Hardness
(°d
German
degrees)
Hardness
(°f
French
degrees)
Setting
level
Regeneratio
n
off
Regeneration
off
H00
8.5
15
H01
11
20
H02
17
30
H03
22.5
40
H04
28
50
H05
Regeneration
cycle
duration:
12
minutes
33.5
60
H06
With
values
over
60°dF
an
external
water
treatment
device
must
be
used
and
the
regeneration
frequency
must
be
set
on
H00
.
6.9
tStP
(minimum
rinsing
temperature)
function
Modify
the
parameter
(ON/OFF)
by
pressing
.
Set
at
“on”
for
minimum
rinsing
temperature
as
set;
set
at
“off”
for
rinsing
regardless
of
boiler
temperature.
If
the
parameter
is
set
as
“off”
and
hot
intake
water
is
not
used,
the
minimum
rinsing
temperature
might
be
a
few
degrees
lower
than
the
setting.