Installation
16
• lf codes permit and a separate ground
wire is used, it is recommended that the
suitability of the ground path be checked
by a qualified electrician.
• When a four-wire or three-wire, single-
phase, 120/208-volt, 60 Hz or 120/
240-volt, 60 Hz, AC-only, electrical
supply is available, a double 50 ampere
maximum circuit protection is required. A
time-delay fuse or circuit breaker is
recommended. The ID Plates are visibly
located on the back of the appliance
and on the oven door frame.
• Wire size and connections must conform
to the requirements of the National
Electrical Code, NFPA 70 or the
Canadian Electric Code, CSA C22.1-
02 or latest edition and all local codes
and ordinances for the kilowatt rating of
the range. IMPORTANT: Observe all
governing codes and ordinances.
• Copies of the standards listed above
may be obtained from:
• (*) National Fire Protection Association,
One Batterymarch Park, Quincy,
Massachusetts 02169-7471
• (**) CSA International 8501 East
Pleasant Valley Road Cleveland, Ohio
44131-5575.
• This appliance is manufactured with a
green-yellow or green ground wire
connected to the oven frame. Make sure
that the power has been turned off then
connect the flexible connector. Connect
the appliance to the junction box using a
UL listed conduit connector. Do not
shorten the flexible metal connector.
• Your local codes and ordinances, of
course, take precedence over these
instructions. Complete electrical
connections according to local codes
and ordinances.
• This range must be connected to a
grounded, metallic, permanent wiring
system or a ground connector should be
connected to the ground terminal or wire
lead on the range.
• Connection at the connection block must
be copper wire only.
NOTE
: Use this method only if
local codes allow connecting the
oven frame ground conductor to
the neutral wire of the power
supply.