Instructions for the installer
84
15.FINAL OPERATIONS
After replacing the nozzles, reposition the flame-spreader crowns, the burner
caps and the pan stands.
Following adjustment to a gas other than the preset one, replace the gas
adjustment label fixed to the appliance with the one corresponding to the new
gas. The label is inserted inside the pack together with the nozzles.
15.1 Adjusting the hob burner minimum setting for city and
natural gas
Light the burner and turn it to the minimum
position. Extract the gas tap knob and turn the
adjustment screw to the top left of the tap rod until
the correct minimum flame is achieved.
Refit the knob and verify that the burner flame is
stable (when turning the knob rapidly from the
maximum to the minimum position the flame must
not go out). Repeat the operation on all gas taps.
For valved models, keep the knob pressed in at the minimum setting for a few
seconds to keep the flame lit and to activate the safety device.
15.2 Adjusting the hob burner minimum setting for LPG
In order to adjust the minimum setting with LPG, the screw at the side of the tap
rod must be tightened clockwise all the way.
The diameters of the by-passes for the individual burners are given in paragraph
“14.2 Burner and nozzle characteristics tables”. When the adjustment is
completed, restore the sealing of the by-passes with paint or another material.
15.3 Positioning and levelling the appliance
After making the electrical and gas connections, level the appliance on the floor
by means of its four adjustable feet. For good cooking results, the appliance
must be properly level.
Summary of Contents for CO68GMA