Make the connection to the gas
mains using a rubber hose whose
specifications comply with current
standards (verify that the reference
standard is stamped on the hose).
Carefully screw the hose connector
3
to the appliance’s gas connector
1
(1/2” thread ISO 228-1), placing the
seal
2
between them. The hose
connector
4
can also be screwed to
the hose connector
3
, depending on
the diameter of the gas pipe used.
After having tightened the hose connector(s), push the gas pipe
6
onto the hose
connector and secure it with the clamp
5
that is compliant with the applicable
standard.
13.3.2 Connection with a flexible steel hose
CAUTION: The following instructions are valid for all types of installation, see
fig. A, B, C in chapter “13.1 Installing in kitchen units”.
Only use standards-compliant continuous wall steel hoses no longer than 2
metres.
This type of installation can be used for both built-in and free-
standing appliances.
Make the connection to the gas mains using a continuous wall
flexible steel pipe whose specifications comply with the
applicable standard.
Carefully screw the connector
3
to the appliance’s gas
connector
1
(1/2” thread ISO 228-1), placing the seal
2
between them.
3
2
1
4
3
6
5
2
1
3
Summary of Contents for CO68GMA