Installation
41
EN
The nozzles not provided are available at Authorised Service Centres.
6 LPG G30/31 - 30/37 mbar
AUX
SR
UR2
Rated heating capacity (kW)
1.0
1.8
4.0
Nozzle diameter (1/100 mm)
50
65
100
Pre-chamber (printed on nozzle)
-
-
-
Reduced flow rate (W)
400
500
1400
Rated flow rate G30 (g/h)
73
131
291
Rated flow rate G31 (g/h)
71
129
286
7 LPG G30/31 - 37 mbar
AUX
SR
UR2
Rated heating capacity (kW)
1.10
1.9
4.1
Nozzle diameter (1/100 mm)
50
65
95
Pre-chamber (printed on nozzle)
-
-
-
Reduced flow rate (W)
450
550
1500
Rated flow rate G30 (g/h)
80
138
298
Rated flow rate G31 (g/h)
79
136
293
8 LPG G30/31 - 50 mbar
AUX
SR
UR2
Rated heating capacity (kW)
1.0
1.8
4.1
Nozzle diameter (1/100 mm)
43
58
80
Pre-chamber (printed on nozzle)
(H2)
(M)
(F4)
Reduced flow rate (W)
400
500
1500
Rated flow rate G30 (g/h)
73
131
298
Rated flow rate G31 (g/h)
71
129
293
9 Town gas G110 - 8 mbar
AUX
SR
UR2
Rated heating capacity (kW)
1.0
1.8
3.4
Nozzle diameter (1/100 mm)
145
185
340
Pre-chamber (printed on nozzle)
/8
/2
0190
Reduced flow rate (W)
400
500