Installation
100
The nozzles not provided are available at Authorised Service Centres.
7 Liquid gas – G30/31 - 30/37 mbar
AUX
SR
FB
R
UR2
Rated heating capacity (kW)
1.0
1.8
1.9
3.0
4.0
Nozzle diameter (1/100 mm)
50
65
68
85
100
Pre-chamber (printed on nozzle)
-
-
-
-
-
Reduced flow rate (W)
400
500
800
800
1400
Rated flow rate G30 (g/h)
73
131
138
218
291
Rated flow rate G31 (g/h)
71
129
136
214
286
8 LPG G30/31 - 37 mbar
AUX
SR
FB
R
UR2
Rated heating capacity (kW)
1.10
1.9
2.0
3.0
4.2
Nozzle diameter (1/100 mm)
50
65
68
81
95
Pre-chamber (printed on nozzle)
-
-
-
-
-
Reduced flow rate (W)
450
550
900
900
1400
Rated flow rate G30 (g/h)
80
138
145
218
305
Rated flow rate G31 (g/h)
79
136
143
214
300
9 LPG G30/31 - 50 mbar
AUX
SR
FB
R
UR2
Rated heating capacity (kW)
1.0
1.8
1.9
3.0
4.1
Nozzle diameter (1/100 mm)
43
58
61
74
80
Pre-chamber (printed on nozzle)
(H2)
(M)
(Z)
(Z)
(F4)
Reduced flow rate (W)
400
500
800
800
1500
Rated flow rate G30 (g/h)
73
131
138
218
298
Rated flow rate G31 (g/h)
71
129
136
214
293
10 Town gas G110 – 8 mbar
AUX
SR
FB
R
UR2
Rated heating capacity (kW)
1.0
1.8
1.9
2.9
3.6
Nozzle diameter (1/100 mm)
145
185
190
260
340
Pre-chamber (printed on nozzle)
/8
/2
/2
/3
-
Reduced flow rate (W)
400
500
800
800
1200