Instructions for the installer
7
For operation on 380-415V3N
∼
:
use an
H05RR-F-type five-core cable (5 x 1.5 mm
2
).
For operation on 380-415V2N
∼
:
use an
H05RR-F-type four-core cable (4 x 1.5 mm
2
).
For operation on 220-240V
∼
:
use an
H05RR-F-type three-core cable (3 x 2.5 mm
2
).
The cable end to be connected to the
appliance must be provided with an ground
wire (yellow-green) at least 20 mm longer.
The manufacturer declines all responsibility
for damage to persons
or things caused by non-observance of the above prescriptions or by
interference with any part of the appliance.
2.2
Ventilation requirements
The room containing the appliance should have an air supply in accordance with
B.S. 5440 part 2 1989.
1.
All rooms require an opening window or equivalent, and some rooms will
require a permanent vent as well.
2.
For room volumes up to 5 m
3
an air vent of 100 cm
2
is required.
3.
If the room has a door that opens directly to the outside, and the room
exceeds 1 m
3
no air vent is required.
4.
For room volumes between 5 m
3
and 10 m
3
an air vent of 50 cm
2
is required.
5.
If there are other fuel burning appliances in the same room B.S. 5440 part 2
1989 should be consulted to determine the air vent requirements.
6.
This appliance must not be installed in a bed sitting room of less than 20 m
3
or in a bathroom or shower room.
Windows and permanent vents should therefore not be blocked or removed
without first consulting a Corgi gas installer.
Failure to install appliances correctly is dangerous and could lead to
prosecution.