. SPECIFICATIONS 

Power 

1300W 

Voltage Range 

200V~240V      50HZ/60HZ 

Temperature range 

100

~500

 

Work time 

000~999seconds/--- 

(

---

  means the unit will work continually) 

Airflow range 

6~200 Level 

Size (L*W*H) 

250*230*150mm 

Weight 

5kg 

 

 

. KEYS AND LCD ILLUMINATE 

 

 

 

 

 

 

 

7.

 

Change  the  password:

  in  the  menu  setting  mode,  press  “CH1”  key  and 

“CH2” key simultaneously, the system will run into the password setting mode. 

The method of the password setting is as following:

 

a)

 

When  in the  password setting  mode, the LCD will  display “

” 

and “

”, the left hundred will flash. 

b)

 

Press

 AIR

 “

”or “

” key to change the hundred digital and then press 

“SAVE” key to ten digital set. Tens digital and one digital setting method 

is the  same  as  the  hundreds  digital setting.  The  setting  method  refers  to 

“6.1  temperature  setting”.  After  finishing  the  first  time  password 

inputting, press “SAVE” key to the secondary password input. 

c)

 

If  the  secondary  inputting  password  is  not  same  with  the  first  inputting 

password,  the  password  setting  is  not  successful  and  it  will  exit  the 

password setting and return to the menu setting.   

d)

 

If  the  secondary  inputting  password  is  same  with  the  first  inputting 

password,  the  password  setting  is  successful.  The  new  password  will 

flash three times and the system will sound “di-di-” and then return to the 

menu setting. 

8.    After finishing menu setting, press “SAVE” key to the work state. 
 

. ERROR MESSAGES 

The  unit  will  give  error  information  when  there  is  something  wrong  with  it  and 

alarms continually before cutting  off the power supply. If the “LCD” display error 

marks as following, please solve them as the troubleshooting.

 

Sensor error: 

If there is some malfunction in the sensor or in the sensor circuit, the 

temperature  parameter  of  LCD  will  display

  “S-E”

  and  the               

power supply to the handle will be cut off.   

Heater  error:

 

If  there  is  some  thing  wrong  with  the  heating  element,  the 

temperature parameter of LCD will display 

“H-E”

 and the power 

supply to the handle will be cut off. 

Motor error:

 If there is some malfunction in the motor or in the motor circuit, the 

airflow  parameter  of  LCD  will  display

  “ERROR”

  and  the  power 

supply to the motor will be cut off.

 

POWER key 

Handle cord 

CH1 key 

CH2 key 

CH3 key 

SAVE key 

INFO key 

AIR key 

TEMP key 

Page3 

Page12 

Summary of Contents for 856AE

Page 1: ...Thank you for purchasing our SMD Rework station The unit is exclusively designed for reworking and soldering SMD component Please carefully read this manual before operating the unit Store this manua...

Page 2: ...truction 5 6 1 Temperature setting 5 6 2 Work time setting 6 6 3 Airflow setting 6 6 4 Magnetism Switch Control 7 6 5 Pedal Switch Control 8 Sleeping 9 7 1 How into the Sleeping State 9 7 2 Resume 10...

Page 3: ...the power cord when not in use for a long time 9 Handle with care not to shock the unit sharply 10 A periodically maintenance of the unit is necessary 11 Don t operate the unit with wet hand or when...

Page 4: ...nt pins must insert into heater localizer and the sensor pins into the sensor localizer CHARACTERISTIC 1 There are three programmable channels CH1 CH2 CH3 and it can set the working time airflow and t...

Page 5: ...password setting and return to the menu setting d If the secondary inputting password is same with the first inputting password the password setting is successful The new password will flash three tim...

Page 6: ...etting The setting method refers to 6 1 temperature setting There are three times to input the password only when the inputting password is right the system runs into the menu setting process Or else...

Page 7: ...t setting temperature If pressing TEMP key not loosely at least one second the setting temperature will drop rapidly Loose the TEMP key until down to the needed temperature 7 2 Resume 1 When the handl...

Page 8: ...tate In the sleeping state the LCD will display and 6 2 Airflow Setting Raise Airflow Click AIR key and then the airflow grade will rise 1 and the LCD displays the current setting airflow grade If pre...

Page 9: ...he temperature and the temperature range is 100 500 The setting method refers to 6 1 temperature setting Press AIR or key to set the airflow and the airflow range is 6 200 The setting method refers to...