Power
1300W
Voltage Range
200V~240V 50HZ/60HZ
Temperature range
100
℃
~500
℃
Work time
000~999seconds/---
(
“
---
”
means the unit will work continually)
Airflow range
6~200 Level
Size (L*W*H)
250*230*150mm
Weight
5kg
Ⅴ
. KEYS AND LCD ILLUMINATE
7.
Change the password:
in the menu setting mode, press “CH1” key and
“CH2” key simultaneously, the system will run into the password setting mode.
The method of the password setting is as following:
a)
When in the password setting mode, the LCD will display “
”
and “
”, the left hundred will flash.
b)
Press
AIR
“
▲
”or “
▼
” key to change the hundred digital and then press
“SAVE” key to ten digital set. Tens digital and one digital setting method
is the same as the hundreds digital setting. The setting method refers to
“6.1 temperature setting”. After finishing the first time password
inputting, press “SAVE” key to the secondary password input.
c)
If the secondary inputting password is not same with the first inputting
password, the password setting is not successful and it will exit the
password setting and return to the menu setting.
d)
If the secondary inputting password is same with the first inputting
password, the password setting is successful. The new password will
flash three times and the system will sound “di-di-” and then return to the
menu setting.
8. After finishing menu setting, press “SAVE” key to the work state.
Ⅹ
. ERROR MESSAGES
The unit will give error information when there is something wrong with it and
alarms continually before cutting off the power supply. If the “LCD” display error
marks as following, please solve them as the troubleshooting.
Sensor error:
If there is some malfunction in the sensor or in the sensor circuit, the
temperature parameter of LCD will display
“S-E”
and the
power supply to the handle will be cut off.
Heater error:
If there is some thing wrong with the heating element, the
temperature parameter of LCD will display
“H-E”
and the power
supply to the handle will be cut off.
Motor error:
If there is some malfunction in the motor or in the motor circuit, the
airflow parameter of LCD will display
“ERROR”
and the power
supply to the motor will be cut off.