background image

 Refer to the back cover for 

identification method.

Pad form

BM

Bellows type with groove

UM

Flat type with groove

BM

BM

w

Weight Difference by Material 

[g]

Pad diameter/form Silicone rubber Urethane rubber

FKM

ZHP63BM

−2.9

0

20.3

ZHP80BM

−5.0

0

35.1

ZHP63UM

−1.5

0

10.6

ZHP80UM

−2.1

0

15.5

RoHS

How to Order

Pad diameter

63

ø63

80

ø80

Exhaust release

S

Silencer exhaust

Pad material

N

NBR (Black)

S

Silicone rubber (White)

U

Urethane rubber (Brown)

F

FKM (Black)

Mounting

Symbol Type

Thread

Size

A

Metric

size

Male

thread

M8

B

M10

C

Female

thread

M8

D

M10

E

Inch

size

Male

thread

5/16-18UNC

F

3/8-16UNC

G

Female

thread

5/16-18UNC

H

3/8-16UNC

Ejector/

Nozzle nominal size [mm]

07

Nozzle: ø0.7

10

Nozzle: ø1.0

12

Nozzle: ø1.2

15

Nozzle: ø1.5

Supply (P) port

Symbol Type

Port size

C4

Metric

ø4 One-touch fitting

C6

ø6 One-touch fitting

N3

Inch

ø5/32" One-touch fitting

N7

ø1/4" One-touch fitting

B

B

N

N

ZHP

ZHP

80

80

With ejector

Without ejector

10

00

Ejector Specifications

ZHP



-07

l

ZHP



-10

ZHP



-12

ZHP



-15

Nozzle nominal size [mm]

0.7

1.0

1.2

1.5

Max. suction flow rate [L/min (ANR)]

30

51

62

77

Air consumption [L/min (ANR)]

24

40

58

87

Vacuum pressure reached [kPa]

−91

Standard supply pressure [MPa]

0.35

 Standard supply pressure

Recommended Work Load

 

[N]

ZHP63

ZHP80

Horizontal lifting

66

106

Vertical lifting

33

53

Use this product with the recommended work 
load  or  less.  The  transfer  work  over  the 
recommended  work  load  may  cause  the 
vacuum pressure to decrease by the air leak. 
The work load shown above is the value when 
the vacuum pressure reaches –85 kPa, and that 
is calculated by multiplying the theoretical value 
by a safety factor of “1/4” for the horizontal lifting 
or “1/8” for the vertical lifting. For details, refer to 
the Vacuum Equipment Model Selection in the 
Best  Pneumatics  No.  4  catalog. The  vacuum 
pressure reached may vary depending on the 
workpiece  (permeability,  etc.)  Calculate  the 
actual work load in accordance with the vacuum 
pressure reached.

Response Time

 

[ms]

ZHP

BM

-07

ZHP

BM

-10

ZHP

BM

-12

ZHP

BM

-15

ø

63

295

143

120

86

ø

80

455

221

190

140

Response time means a period of time that the vacuum pressure reaches –57 kPa after the externally 
installed valve has been turned ON when the bellows type pad is used and the supply pressure is 0.35 MPa.

Nozzle size

Pad dia.

Weight

Material: NBR, Mounting: 

A 

[g]

ZHP63BMNA-

C6S

184

ZHP80BMNA-

C6S

224

ZHP63UMNA-

C6S

167

ZHP80UMNA-

C6S

175

For the ZHP



A-00 (without ejector), weight shown above –12 g.

When the mounting symbol is other than “A”, add the weight 

q

 shown in the table on 

the right to the weight described in the table above.

When the material is other than NBR, add the weight 

w

 shown in the table on the 

right to the weight described in the table above.

This weight includes the accessory weight.

q

Weight Difference by Mounting Style 

[g]

B

C

D

E

F

G

H

20

−5

14

7

25

1

11

S

Vacuum Pad with Ejector

Series

 ZHP

ø

63, ø80

C6

2

Summary of Contents for ZHP Series

Page 1: ...n surface Workpieces can be removed easily 2 Compared with current ZP series Dents and bumps on the adsorption surface prevent the workpiece from sticking to it This facilitates easy removal With groo...

Page 2: ...steps Easier maintenance Holder Holder Plate Pad Robot handling Palletizing Automobile Case packer Application Examples Series ZHP 1 Pad diameter Pad form Pad material Mounting Nozzle nominal size 2 m...

Page 3: ...rk load or less The transfer work over the recommended work load may cause the vacuum pressure to decrease by the air leak The work load shown above is the value when the vacuum pressure reaches 85 kP...

Page 4: ...consumption L min ANR ZHP 10 100 90 80 70 60 50 40 30 20 10 0 100 90 80 70 60 50 40 30 20 10 0 0 0 1 0 2 0 3 0 4 0 5 0 6 Supply pressure MPa Vacuum pressure kPa Suction flow L min ANR Air consumption...

Page 5: ...A00284 Included 3 pieces are included in one product The part numbers are for 1 piece Component Parts Replacement Parts Construction Replacement Parts How to Order Pad diameter 63 63 80 80 When changi...

Page 6: ...0 85 18 41 8 ZHP63UM 26 63 66 5 20 3 ZHP80UM 26 80 83 5 20 3 Supply Port Dimensions mm N C4 4 7 C6 4 7 N3 4 7 N7 7 3 Adapter Dimensions by Mounting Style mm G H J K L M ZHPmmmA mmS 25 7 22 6 5 13 M8 Z...

Page 7: ...ies ZHP Specific Product Precautions 1 Be sure to read this before handling For Safety Instructions and Vacuum Equipment Precautions refer to Handling Precautions for SMC Products and the Operation Ma...

Page 8: ...te 9 When using the male thread mounting type product do not loosen the bottom nut shown in the figure below The bottom nut is intended to secure the connection between the bracket for the adapter con...

Reviews: