background image

Quick Start Guide

–  6  –

Hardware Specifications

Item

Specification

Chassis Specifications

Size

W x D x H: 140 x 140 x 47.8 mm (5.51 x 5.51 x 1.88 inches)

Weight

500 g (1.10 lbs)

Temperature

Operating: 0 °C to 40 °C (32 °F to 104 °F)
Storage: -20 °C to 70 °C (-4 °F to 158 °F)

Humidity

Operating: 5% to 95% (non-condensing)

Network Interfaces

Ports

One RJ-45 Port: 1000BASE-T, PoE (PD)

2.4GHz Radio

IEEE 802.11b/g/n

5 GHz Radio

IEEE 802.11a/n

Radio Frequencies

2400 ~ 2483.5 MHz
2412 ~ 2472 MHz
5745 ~ 5825 MHz (China)
5180 ~ 5320 MHz (ETSI)
5500 ~ 5700 MHz (ETSI)

Power Supply Specifications

PoE Input Power

48 VDC, 0.3A

AC Power Adapter

AC Input: 100 ~ 240 VAC
DC Output: 12 VDC, 2 A

Power Consumption

22.5 W maximum

Regulatory Compliances

Radio

ETSI 300 328 (802.11b/g)
ETSI 301 893 (802.11a Full range)
ETSI 301 489 (DC power)
FCC Part 15C 15.247/15.207 (2.4-2.4835GHz, 5.725-5.850GHz)
FCC Part 15E 15.407 (5.150GHz-5.250GHz)
NCC LP0002 (2.4-2.4835GHz, 5.250-5.350GHz, 5.725-5.850GHz)

Emissions

EN 55022:2007, Class A/B
IEC 61000-3-2/3
FCC Class B Part 15
CNS13438

Immunity

EN 55024:2001 + A2:2003
IEC 61000-4-2/3/4/5/6/8/11

Safety

CSA c us (CSA/UL60950-1)
CB (IEC60950-1)

Summary of Contents for WAP5110-L

Page 1: ...n be powered through a PoE cable connection from a PoE network switch or from its AC power adapter In addition the AP supports network management from an SMC WAC4502 wireless access controller throught the Control and Provisioning of Wireless Access Points CAPWAP protocol NOTE For detailed access point AP installation information refer to the Installation Guide which is on the Documentation CD inc...

Page 2: ...recommended to consult a professional contractor knowledgeable in local radio regulations prior to equipment installation Follow these steps to install the AP 1 Unpack the AP Unpack the AP and check the package contents WAP5110 L Enterprise Access Point AC Power adapter Console cable RJ 45 to DB 9 Quick Start Guide this guide Regulatory and Safety Information Documentation CD includes Installation...

Page 3: ...nection The RJ 45 port connection can also provide PoE power to the unit 1 2 Mounting on a Ceiling T rail Position the AP s ceiling mount clip holders on either side of the T rail Turn the AP until the two clips lock the AP to the T rail 1 2 Connect Category 5e or better cable to the RJ 45 port 1 1 ...

Page 4: ...an AC power source 5 Verify AP Operation Verify basic AP operation by checking the system LEDs The Power LED should be on green and the Network LED on or flashing amber Connect the power adapter to the power socket Connect the power adapter to a nearby AC power source 1 2 1 2 Network Link Activity Power Diagnostic 2 1 1 2 ...

Page 5: ...ers Parity None Stop bit One Data bits 8 Flow control none Log in to the command line interface CLI using default settings Login Name admin Password null there is no default password For information on manually configuring an IP address for the AP refer to the Installation Guide which is on the Documentation CD included with the AP For further information on AP configuration and CLI commands refer...

Page 6: ...472 MHz 5745 5825 MHz China 5180 5320 MHz ETSI 5500 5700 MHz ETSI Power Supply Specifications PoE Input Power 48 VDC 0 3A AC Power Adapter AC Input 100 240 VAC DC Output 12 VDC 2 A Power Consumption 22 5 W maximum Regulatory Compliances Radio ETSI 300 328 802 11b g ETSI 301 893 802 11a Full range ETSI 301 489 DC power FCC Part 15C 15 247 15 207 2 4 2 4835GHz 5 725 5 850GHz FCC Part 15E 15 407 5 15...