Specific Product Precautions
Be sure to read before handling.
Refer to front matter 53 for Safety Instructions and pages 3 to 8 for 3/4/5 Port
Solenoid Valve Precautions.
Connected actuator is started by manual operation.
Use the manual override after confirming that there is
no danger.
Warning
Caution
Non-locking push type (Tool required)
VQD1151W-
:
(For switching)
10-VQ110-
:
-X46
(For charging
release air)
Attaching and detaching connectors
#
To attach a connector, hold the lever and connector unit between
your fingers and insert straight onto the pins of the solenoid valve
so that the lever’s pawl is pushed into the groove and locks.
#
To detach a connector, remove the pawl from the groove by
pushing the lever downward with your thumb, and pull the
connector straight out.
Note) Gently pull the lead wire, otherwise it may cause contact failure or disconnection.
Caution
VQD1151W-
:
(For switching)
For the VQD1151W specifications (energy saving type), power
consumption at holding is reduced with the above circuit.
Refer to electrical power waveform as shown below.
<Energy saving type’s electrical power waveform>
(Rated voltage: at 24 VDC)
Caution
When simultaneously energizing 3 stations or more,
make sure to place an energized and non-energized
valve alternatively.
However, if 3 stations or more need to be energized si-
multaneously at the time of installing or adjusting, the
energizing time should be less than 30 minutes to
achieve an energized status not exceeding 50%.
24 V
0 V
3.2 W
2.4 W
0 W
15 to 25 ms
Applied voltage
Cover
Groove
Pin
Lever
Connector
Lever
Connector
ø3
push part
Caution
After confirming the gasket is correctly placed under
the valve, securely tighten the bolts with the proper
torque shown in the table below.
s )N ORDER TO TURN IT /. PUSH DOWN THE MANUAL
override button in the direction the arrow ( )
indicates until it stops (approx. 0.5 mm), and
RELEASEITTOTURNIT/&&
Manual Override Operation
Valve Mounting
Caution
When piping to a product, check the supply port, etc.
Also, when tightening the piping tube, clamp the base unit to
avoid any undue force from being applied to the valve.
)F A FORCE OF . OR MORE IS APPLIED TO THE COIL ESPECIALLY THE
connecting pin may be deformed, resulting in malfunction.
When Piping to a Product
How to Use Plug Connector
Wiring Specifications
Proper tightening torque (N · m)
0.18 to 0.25
10-VQ110-
:
-X46
(For charging release air)
Coil temperature may get high due to ambient tempera-
ture or energizing duration. Do not touch the valve by
hand directly. When there is such a dangerous case to
be touched by hand directly, install a protective cover.
Warning
Continuous Energization
Energy saving type
3/,
3/,
A
C
Black (−)
Red (+)
Lead wire
Energy
saving
)#
Diode
Varistor
A
C
Lead wire
LED
Black (−,+)
Red (+,−)