VQD1000-V

Specific Product Precautions

Be sure to read before handling.
Refer to front matter 53 for Safety Instructions and pages 3 to 8 for 3/4/5 Port 
Solenoid Valve Precautions.

Connected actuator is started by manual operation. 
Use the manual override after confirming that there is 
no danger.

Warning

Caution

 

 Non-locking push type (Tool required)

VQD1151W-

:

(For switching)

10-VQ110-

:

-X46

(For charging 
release air)

Attaching and detaching connectors

#

 To attach a connector, hold the lever and connector unit between 

your fingers and insert straight onto the pins of the solenoid valve 
so that the lever’s pawl is pushed into the groove and locks.

#

 To detach a connector, remove the pawl from the groove by 

pushing the lever downward with your thumb, and pull the 
connector straight out.

Note) Gently pull the lead wire, otherwise it may cause contact failure or disconnection.

Caution

VQD1151W-

:

(For switching)

For the VQD1151W specifications (energy saving type), power 
consumption at holding is reduced with the above circuit.
Refer to electrical power waveform as shown below.

<Energy saving type’s electrical power waveform>
(Rated voltage: at 24 VDC)

Caution

When simultaneously energizing 3 stations or more, 
make sure to place an energized and non-energized 
valve alternatively. 
However, if 3 stations or more need to be energized si-
multaneously at the time of installing or adjusting, the 
energizing time should be less than 30 minutes to 
achieve an energized status not exceeding 50%.

24 V

0 V

3.2 W

2.4 W

0 W

15 to 25 ms

Applied voltage

Cover

Groove

Pin

Lever

Connector

Lever

Connector

ø3 

push part

Caution

After confirming the gasket is correctly placed under 
the valve, securely tighten the bolts with the proper 
torque shown in the table below.

s )N ORDER TO TURN IT /. PUSH DOWN THE MANUAL

override button in the direction the arrow (    ) 
indicates until it stops (approx. 0.5 mm), and 

RELEASEITTOTURNIT/&&

Manual Override Operation

Valve Mounting

Caution

When piping to a product, check the supply port, etc.

Also, when tightening the piping tube, clamp the base unit to 
avoid any undue force from being applied to the valve.

)F A FORCE OF  . OR MORE IS APPLIED TO THE COIL ESPECIALLY THE

connecting pin may be deformed, resulting in malfunction.

When Piping to a Product

How to Use Plug Connector

Wiring Specifications

Proper tightening torque (N · m)

0.18 to 0.25

10-VQ110-

:

-X46

(For charging release air)

Coil temperature may get high due to ambient tempera-
ture or energizing duration. Do not touch the valve by 
hand directly. When there is such a dangerous case to 
be touched by hand directly, install a protective cover.

Warning

Continuous Energization

Energy saving type

3/,

3/,

A

C

Black (−)

Red (+)

Lead wire

Energy

saving

)#

Diode

Varistor

A

C

Lead wire

LED

Black (−,+)

Red (+,−)

1967

VV100

VV061

V100

S070

VQD

VQD-V

VKF

VK

VT

VS4

VS3

VQD-V