background image

Series 

VMG

Specific Product Precautions 1

Be sure to read this before handling.

Male thread

R 1/4

R 3/8

Tightening torque N

m

12 to 14

22 to 24

Port

Spanner

Wrapping 
direction

Pipe tape

Expose approx. 2 threads.

Nozzle tightening torque range

12 to 14 N

m

Nozzle holder

Spanner

Insufficient tightening may cause loosening of the nozzle.

1. Do not apply the blow gun to flammable, 

explosive or toxic substances such as gas, 
fuel gas or refrigerant. Such substances 
may exude from inside the blow gun.

1.  Install a stop valve on the supply pressure 

side of the blow gun to enable emergency shut 
off in case of unexpected leakage or damage.

2. When installing a nozzle on the blow gun, wrap 

pipe tape around the threads of the nozzle.

3.  When installing the nozzle, secure the 

nozzle holder of the blow gun by applying a 
spanner of 22 mm width across flats to the 
two chamfered surfaces of the holder 
without applying force to the body. Then, 
tighten the nozzle with force within the 
below torque range. As a guideline, it is 
equivalent to 2 to 3 additional turns with a 
tool after manual tightening.

1. Check the specifications.

The products in this catalog are designed to be used in 
compressed air systems only. If the products are used in an 
environment where pressure or temperature is out of the specified 
range, damage and/or malfunction may result. Do not use under 
such conditions.

Selection

Mounting

Warning

Warning

1. Check the model, type and size before 

installation.

Also, confirm that there is no scratches, gouges or cracks on the 
product.

2. Before piping

Before piping, it should be thoroughly blown out with air (flushing) 
or washed to remove chips, cutting oil and other debris from 
inside the pipe.

Piping

Caution

Caution

3. Wrapping of pipe tape

When screwing together pipes and fittings, etc., be certain that 
chips from the pipe threads and sealing material do not get inside 
the blow gun. Also, when the pipe tape is used, leave 1.5 to 2 
thread ridges exposed at the end of the threads.

Piping

Caution

4.  When tightening the threads, secure the 

nozzle holder of the blow gun by applying a 
spanner of 22 mm width across flats to the 
two chamfered surfaces of the holder 
without applying force to the body. Then, 
tighten the nozzle with torque specified in 
the below table. As a guideline, it is 
equivalent to 2 to 3 additional turns with a 
tool after manual tightening.

Be careful that tightening with torque beyond the ranges in the 
below table may cause damage to the body.

5. Allow extra length when connecting a tube 

to accommodate changes in tube length due 
to pressure.

6. Confirm that no twisting, turning or tensile 

force or moment load is applied to the port 
or tube. This may cause fittings to fracture 
or tubes to be crushed, burst or come loose.

7. Do not abrade, entangle or scratch the tube. 

This may cause the tube to be crushed, 
burst or come loose.

1. Use clean air.

Do not use compressed air which includes chemicals, synthetic 
oils containing organic solvents, salt or corrosive gases, etc., as it  
can cause damage or malfunction.

Air Supply

Warning

1. Do not lubricate the product.

It may contaminate or damage the target object.

Lubrication

Warning

5

VMG-D.qxd  10.1.15 4:19 PM  Page 10

Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Summary of Contents for VMG Series

Page 1: ...mpressors for air accounts for approximately 20 of that consumed by the entire factory Also 70 of the air consumed in the process is used for air blowing SMC blow guns have minimal pressure loss compared with conventional models so they can achieve equivalent performance at lower pressures and with less volume of air consumption As a result it is possible to achieve a 20 reduction in power consump...

Page 2: ...yen for a total yearly saving of 38 595 yen or 20 of the total 240 220 200 180 160 140 120 100 5 000 6 000 7 000 8 000 9 000 10 000 Total working hours of use Cost of electricity consumed by compressor thousands of yen 240 220 200 180 160 140 120 100 5 000 6 000 7 000 8 000 9 000 10 000 Total working hours of use Cost of electricity consumed by compressor thousands of yen Calculation conditions Wo...

Page 3: ...del Conventional model Nozzle size ø3 6 8 mm2 6 mm2 6 3 mm2 TCU1065 1 20 X6 S coupler VMG Nozzle size ø2 5 13 45 mm2 30 mm2 4 4 mm2 0 011 MPa at a distance of 100 mm 0 5 MPa 0 276 MPa 0 011 MPa at a distance of 100 mm 0 4 MPa 0 385 MPa Coupler Piping Air gun Coupler Piping S0 Air gun S1 Nozzle S2 Impact pressure Effective area ratio S0 to S1 S2 Compressor pressure Air consumption Power consumption...

Page 4: ...a 30 mm2 effective area Method Process Effects Features Energy saving So Thus Required less air consumption Effective discharge at low pressure Smaller nozzle diameter Lower discharge pressure from compressor Reduction in the amount of electricity consumed by compressor Pressure drop Small High pressure right before the nozzle Effective area Large TCU0604 20 1 X6 KQ2H06 02S Up to 20 mm VMG1쏔쏔 02 0...

Page 5: ...t from a 2 meter height or in a human stomp test Not affected by supply pressure assured operability Not affected by supply pressure assured operability Components are separable Environmentally friendly Components are separable Environmentally friendly Use of shock resistant resin Use of shock resistant resin Resin PBT Seals NBR Nozzle Brass Metal Aluminum alloy Stainless steel Recyclable Secures ...

Page 6: ...Effective area Port size Piping entry Nozzle port size Weight Operational force when the valve is fully open Air 0 to 1 0 MPa 1 5 MPa 5 to 60 C No freezing 30 mm2 without nozzle Rc NPT G 1 4 3 8 Rc 1 4 180 g 7 N Top Ambient and fluid temperature Bottom Note 1 S couplers and fittings are included Note 2 In the case of S coupler plug type the port size is Rc 1 4 Note 3 In the case of metric size one...

Page 7: ...5 0 6 0 7 0 8 0 9 1 KNH R02 200 KNH R02 150 KNH R02 100 400 350 300 250 200 150 100 50 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 KNL3 06 200 KNL3 06 150 KNL6 06 200 KNL6 06 150 900 800 700 600 500 400 300 200 100 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 9 1 KNS R02 110 8 KNS R02 090 8 KNS R02 100 4 KNS R02 075 4 Supply pressure MPa Flow rate l min ANR Supply pressure MPa Flow rate l min ANR Supply pressu...

Page 8: ...rence dimensions after installation mm KN R02 100 KN R02 150 KN R02 200 KN R02 250 KNH R02 100 KNH R02 150 KNH R02 200 KNS R02 075 4 KNS R02 090 8 KNS R02 100 4 KNS R02 110 8 KNL3 06 150 KNL3 06 200 KNL6 06 150 KNL6 06 200 ø1 ø1 5 ø2 ø2 5 ø1 ø1 5 ø2 ø0 75 x 4 ø0 9 x 8 ø1 x 4 ø1 1 x 8 ø1 5 ø2 ø1 5 ø2 23 4 23 22 5 22 1 44 44 44 12 12 12 12 305 3 305 3 605 3 605 3 Type Metric size one touch fitting I...

Page 9: ...installation Nozzle size D Connection thread L1 A Width across flats H1 Low noise nozzle with male thread KNS mm KNS R02 075 4 KNS R02 090 8 KNS R02 100 4 KNS R02 110 8 ø0 75 x 4 ø0 9 x 8 ø1 x 4 ø1 1 x 8 R 1 4 R 1 4 R 1 4 R 1 4 14 14 14 14 20 20 20 20 14 14 14 14 Model Reference dimensions after R thread installation Nozzle size D Connection thread L1 A Width across flats H1 Copper extension nozzl...

Page 10: ...uld be thoroughly blown out with air flushing or washed to remove chips cutting oil and other debris from inside the pipe Piping Caution Caution 3 Wrapping of pipe tape When screwing together pipes and fittings etc be certain that chips from the pipe threads and sealing material do not get inside the blow gun Also when the pipe tape is used leave 1 5 to 2 thread ridges exposed at the end of the th...

Page 11: ...use in an environment where the product is exposed to such liquid as cutting oil lubricating oil or coolant oil Operating Environment Warning 1 In periodical inspections check the follow ing items and replace the parts if necessary a Scratches gouges abrasion corrosion b Air leakage c Twisting crushing and turning of connected tubes d Hardening deterioration and softening of connected tubes e Loos...

Page 12: ...hich requires the provision of double interlock for possible failure by using a mechanical protective function and periodical checks to confirm proper operation Warning Limited warranty and Disclaimer Compliance Requirements The product used is subject to the following Limited warranty and Disclaimer and Compliance Requirements Read and accept them before using the product 1 The product is provide...

Reviews: