2.1 Specifications

Note 1)

In accordance with dynamic performance test of JIS B 8374-1981 (coil temperature 20ºC,
at rated voltage, without surge voltage suppressor)

Note 2)

Impact resistance

: No malfunction resulted from test using a drop impact tester. The test

was performed one time each in the axial and right angle directions of the main valve and
armature, for both energized and de-energized status

Vibration resistance

: No malfunction resulted in a 45 to 2000Hz one sweep test

performed in the axial and right angle directions of the main valve and armature, for both
energized and de-energized status.

2.2 Circuit Symbols

3

INSTALLATION

WARNING

Do not install unless the safety instructions have been read and understood.

3.1 Environment

WARNING

Do not use in an environment where the product is directly exposed to corrosive gases, chemicals,
salt water, water or steam.

Do not use in an explosive atmosphere.

The product should not be exposed to prolonged sunlight. Use a protective cover.

Do not mount the product in a location where it is subject to strong vibrations and/or shock. Check
the product specifications for above ratings.

Do not mount the product in a location where it is exposed to radiant heat.

Read this manual before using this product. 

The information within this document is to be used by pneumatically trained personnel only.

For future reference, please keep manual in a safe place.

This manual should be read in conjunction with the current catalogue.

1

SAFETY RECOMMENDATION

1.1 General recommendation

These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These
instructions indicate the level of potential hazard by label of "Caution", "Warning" or "Danger". To ensure safety,
be sure to observe ISO4414 (Note1), JIS B 8370 (Note2) and other safety practices.

Note1: ISO 4414: Pneumatic fluid power - General rules relating to systems. 

Note2: JIS B 8370:Pneumatic system axiom.

WARNING

The compatibility of pneumatic equipment is the responsibility of the person who designs the
pneumatic system or decides its specifications.

Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements.

Only trained personnel should operate pneumatically operated machinery and equipment.

Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.

Do not service machinery/equipment or attempt to remove components until safety is confirmed.

Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe
locked-out control positions.

When equipment is to be removed, confirm the safety process as mentioned above. Switch off air and
electrical supplies and exhaust all residual compressed air in the system.

Before machinery/equipment is re-started, ensure all safety measures to prevent sudden movement of
cylinders etc. (Bleed air into the system gradually to create backpressure, i.e. incorporate a soft-start
valve).

Contact SMC if the product is to be used in any of the following conditions:

Conditions and environments beyond the given specifications, or if product is used outdoors.

Installations on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical
equipment, food and beverage, recreation equipment, emergency stop circuits, press applications, or
safety equipment.

An application, which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis. 

CAUTION

Ensure that the air supply system is filtered to 5 micron.

1.2 Conformity to standard

This product if certified to and complies with the following standards:

3.2 Piping

CAUTION

Before piping make sure to clean up chips, cutting oil, dust etc.

When installing piping or fitting into a port, ensure that sealant material does not enter the port inside.
When using seal tape, leave 1.5 to 2 threads exposed on the end of pipe/fitting. 

Installation and Maintenance Manual

Series VKF300
3 Port Direct Operated Poppet Solenoid Valve

CAUTION:

Operator error could result in injury or equipment damage.

WARNING:

Operator error could result in injury or loss of life.

DANGER:

In extreme conditions, there is possible result of serious injury or loss of life.

Valve specifications

Type of operation

Direct operated 2 position single solenoid

Operating fluid

Air

Operating pressure range

Standard

0~0.7MPa

Vacuum

-101.2kPa~0.1MPa

Ambient and fluid temperature

Maximum 50°C

Response time 

Note 1

)

Standard

10ms or less

Low power consumption

15ms or less

Manual operation

Non-lock push style

Lubrication

Not required

Mounting position

Unrestricted

Impact resistance/vibration resistance 

Note 2

)

300/50 m/s

2

Enclosure

Dust proof

Electrical specifications

Electrical entry

Grommet (G), DIN terminal (D)

Rated voltage

AC

100V, 110V, 200V, 220V, 240V

DC

6V, 12V, 24V, 48V

Allowable voltage fluctuation

±10% of rated voltage

Standard

Starting

9.5VA/50Hz, 8VA/60Hz

Holding

7VA/50Hz, 5VA/60Hz

Power consumption (DC)

Without light

4W (standard), 2W (low power consumption type)

With light

4.3W (standard), 2.3W (low power consumption type)

Surge voltage suppressor

AC

Varistor

DC

Diode (varistor for 12VDC or less)

Indicator light

AC

Neon bulb

DC

LED

Apparent
power (AC)

EMC Directive 

EN 61000-6-2, EN 55011

Low Voltage Directive 

DIN VDE 0580

Thread

Appropriate tightening torque (Nm)

M5

1.5 to 2

Rc 1/8

7 to 9

X

Symbol

(A)

2

1

(P)

3

(R)

Rc 1/8
(port A)

Rc 1/8,
M5x0.8
(port A)

2-M5x0.8
(ports P, R)

Rc 1/8
(port P, R)

Single type, body ported type

Single type, base mounted type

Manifold, body ported type.
Common SUP, Common EXH

Manifold, body ported type.
Common SUP, Individual EXH

Port A:
Rc 1/8, M5x0.8

Port R: Rc 1/8

Port P: Rc 1/8

Type 21/for body ported type
(Port A top ported)

Port A:
Rc 1/8, M5x0.8

Port P: Rc 1/8

Type 20/for body ported type
(Port A top ported)

Port R: Rc 1/8

Manifold, base mounted type.
Common SUP, Common EXH

Port R: Rc 1/8

Type 42/for base mounted type
(Port A side ported)

Port P: Rc 1/8

Type 40/for base mounted type
(Port A bottom ported)

Port R: Rc 1/8

Port P: Rc 1/8

Port A: Rc 1/8

Port A: Rc 1/8

Type S42
(solenoid on same side as port A)

Port P: Rc 1/8

Port R: Rc 1/8

Port A: Rc 1/8

VKF300-TFH35GB 