2
INTENDED CONDITIONS OF USE
2.1 Specifications
Note 1)
In accordance with dynamic performance test of JIS B 8374-1981 (coil temperature 20ºC,
at rated voltage, without surge voltage suppressor)
Note 2)
Impact resistance
: No malfunction resulted from test using a drop impact tester. The test
was performed one time each in the axial and right angle directions of the main valve and
armature, for both energized and de-energized status
Vibration resistance
: No malfunction resulted in a 45 to 2000Hz one sweep test
performed in the axial and right angle directions of the main valve and armature, for both
energized and de-energized status.
2.2 Circuit Symbols
3
INSTALLATION
WARNING
Do not install unless the safety instructions have been read and understood.
3.1 Environment
WARNING
Do not use in an environment where the product is directly exposed to corrosive gases, chemicals,
salt water, water or steam.
Do not use in an explosive atmosphere.
The product should not be exposed to prolonged sunlight. Use a protective cover.
Do not mount the product in a location where it is subject to strong vibrations and/or shock. Check
the product specifications for above ratings.
Do not mount the product in a location where it is exposed to radiant heat.
Read this manual before using this product.
The information within this document is to be used by pneumatically trained personnel only.
For future reference, please keep manual in a safe place.
This manual should be read in conjunction with the current catalogue.
1
SAFETY RECOMMENDATION
1.1 General recommendation
These safety instructions are intended to prevent a hazardous situation and/or equipment damage. These
instructions indicate the level of potential hazard by label of "Caution", "Warning" or "Danger". To ensure safety,
be sure to observe ISO4414 (Note1), JIS B 8370 (Note2) and other safety practices.
Note1: ISO 4414: Pneumatic fluid power - General rules relating to systems.
Note2: JIS B 8370:Pneumatic system axiom.
WARNING
The compatibility of pneumatic equipment is the responsibility of the person who designs the
pneumatic system or decides its specifications.
Since the products specified here are used in various operating conditions, their compatibility for the
specific pneumatic system must be based on specifications or after analysis and/or tests to meet your
specific requirements.
Only trained personnel should operate pneumatically operated machinery and equipment.
Compressed air can be dangerous if an operator is unfamiliar with it. Assembly, handling or repair of
pneumatic systems should be performed by trained and experienced operators.
Do not service machinery/equipment or attempt to remove components until safety is confirmed.
Inspection and maintenance of machinery/equipment should only be performed after confirmation of safe
locked-out control positions.
When equipment is to be removed, confirm the safety process as mentioned above. Switch off air and
electrical supplies and exhaust all residual compressed air in the system.
Before machinery/equipment is re-started, ensure all safety measures to prevent sudden movement of
cylinders etc. (Bleed air into the system gradually to create backpressure, i.e. incorporate a soft-start
valve).
Contact SMC if the product is to be used in any of the following conditions:
Conditions and environments beyond the given specifications, or if product is used outdoors.
Installations on equipment in conjunction with atomic energy, railway, air navigation, vehicles, medical
equipment, food and beverage, recreation equipment, emergency stop circuits, press applications, or
safety equipment.
An application, which has the possibility of having negative effects on people, property, or animals,
requiring special safety analysis.
CAUTION
Ensure that the air supply system is filtered to 5 micron.
1.2 Conformity to standard
This product if certified to and complies with the following standards:
3.2 Piping
CAUTION
Before piping make sure to clean up chips, cutting oil, dust etc.
When installing piping or fitting into a port, ensure that sealant material does not enter the port inside.
When using seal tape, leave 1.5 to 2 threads exposed on the end of pipe/fitting.
Installation and Maintenance Manual
Series VKF300
3 Port Direct Operated Poppet Solenoid Valve
CAUTION:
Operator error could result in injury or equipment damage.
WARNING:
Operator error could result in injury or loss of life.
DANGER:
In extreme conditions, there is possible result of serious injury or loss of life.
Valve specifications
Type of operation
Direct operated 2 position single solenoid
Operating fluid
Air
Operating pressure range
Standard
0~0.7MPa
Vacuum
-101.2kPa~0.1MPa
Ambient and fluid temperature
Maximum 50°C
Response time
Note 1
)
Standard
10ms or less
Low power consumption
15ms or less
Manual operation
Non-lock push style
Lubrication
Not required
Mounting position
Unrestricted
Impact resistance/vibration resistance
Note 2
)
300/50 m/s
2
Enclosure
Dust proof
Electrical specifications
Electrical entry
Grommet (G), DIN terminal (D)
Rated voltage
AC
100V, 110V, 200V, 220V, 240V
DC
6V, 12V, 24V, 48V
Allowable voltage fluctuation
±10% of rated voltage
Standard
Starting
9.5VA/50Hz, 8VA/60Hz
Holding
7VA/50Hz, 5VA/60Hz
Power consumption (DC)
Without light
4W (standard), 2W (low power consumption type)
With light
4.3W (standard), 2.3W (low power consumption type)
Surge voltage suppressor
AC
Varistor
DC
Diode (varistor for 12VDC or less)
Indicator light
AC
Neon bulb
DC
LED
Apparent
power (AC)
EMC Directive
EN 61000-6-2, EN 55011
Low Voltage Directive
DIN VDE 0580
Thread
Appropriate tightening torque (Nm)
M5
1.5 to 2
Rc 1/8
7 to 9
X
Symbol
(A)
2
1
(P)
3
(R)
Rc 1/8
(port A)
Rc 1/8,
M5x0.8
(port A)
2-M5x0.8
(ports P, R)
Rc 1/8
(port P, R)
Single type, body ported type
Single type, base mounted type
Manifold, body ported type.
Common SUP, Common EXH
Manifold, body ported type.
Common SUP, Individual EXH
Port A:
Rc 1/8, M5x0.8
Port R: Rc 1/8
Port P: Rc 1/8
Type 21/for body ported type
(Port A top ported)
Port A:
Rc 1/8, M5x0.8
Port P: Rc 1/8
Type 20/for body ported type
(Port A top ported)
Port R: Rc 1/8
Manifold, base mounted type.
Common SUP, Common EXH
Port R: Rc 1/8
Type 42/for base mounted type
(Port A side ported)
Port P: Rc 1/8
Type 40/for base mounted type
(Port A bottom ported)
Port R: Rc 1/8
Port P: Rc 1/8
Port A: Rc 1/8
Port A: Rc 1/8
Type S42
(solenoid on same side as port A)
Port P: Rc 1/8
Port R: Rc 1/8
Port A: Rc 1/8
VKF300-TFH35GB