background image

Flow Rate Characteristics

Standard Specifications

Option/Part Nos.

Specifications

Model

VHS20-D

VHS30-D

VHS40-D VHS40-06-D VHS50-D

Applicable AC size

AC20-D

AC30-D

AC40-D

AC40-06-D

AC50-D

AC60-D

*

1

Fluid

Air

Ambient and fluid temperatures

−5 to 60

°

C (No freezing)

Proof pressure

1.5 MPa

Max. operating pressure

1.0 MPa

Handle switching angle

90

°

Paint color

Handle: Red

Body: White

Body cover: White

Weight

0.10 kg

0.18 kg

0.40 kg

0.43 kg

0.82 kg

*

1  The VHS50 can be connected to the AC60.

Optional 

specifications

Model

VHS20-D

VHS30-D

VHS40-D

VHS40-06-D

VHS50-D

Bracket
assembly

*

1

VHS24P-180AS VHS34P-180AS VHS44P-180AS VHS44P-180AS VHS54P-180AS

Silencer
assembly

*

2

VHS24P-190AS VHS34P-190AS VHS44P-190AS VHS54P-190AS VHS54P-190AS

*

1  The assembly consists of a bracket A/B and 2 mounting screws.

*

2  The assembly consists of the element assembly and an O-ring.

Model

Port size

Flow rate characteristics

IN, OUT

EXH

IN 

R

 OUT

OUT 

R

 EXH

C (dm

3

/s·bar)

b

Cv

C (dm

3

/s·bar)

b

Cv

VHS20-D

1/8

1/8

4.0

0.41

1.1

3.7

0.42

1.1

1/4

5.8

0.31

1.4

3.8

0.42

1.1

VHS30-D

1/4

1/4

8.8

0.44

2.4

8.0

0.46

2.3

3/8

14.1

0.28

3.5

7.8

0.46

2.2

VHS40-D

1/4

3/8

9.5

0.49

2.8

13.3

0.47

3.6

3/8

17.2

0.47

4.8

13.6

0.47

3.7

1/2

26.7

0.29

6.3

13.4

0.43

3.7

VHS40-06-D

3/4

1/2

34.0

0.22

7.6

16.1

0.41

4.4

VHS50-D

3/4

1/2

45.0

0.26

10.6

23.0

0.49

6.4

1

53.3

0.36

13.5

22.8

0.49

6.3

OSHA standard (Occupational Safety and Health 
Administration, U.S. Department of Labor)
For safety control, OSHA rule requires 
energy sources for certain equipment 
be turned off or disconnected and that 
the device either be locked or labelled 
with a warning tag.

Cross section of EXH port

with built-in silencer assembly

Bracket assembly

Option “S”

With built-in silencer

(for EXH port)

Option “B”

With bracket

O-ring

Bracket A

Mounting screw

Bracket B

Element 
assembly

4

OSHA Standard Compliant

Pressure Relief 3-Port Valve with Locking Holes  

VHS20/30/40/50-D 

Series

Summary of Contents for VHS20-D Series

Page 1: ...during switching of the handle OSHA Occupational Safety and Health Administration standard compliant Variations Single action VHS20 D VHS30 D VHS40 D VHS40 06 D VHS50 D Double action VHS20W D VHS30W...

Page 2: ...D VHS40 04 D VHS50 10 D Single Action VHS20 30 40 50 D Series Double Action VHS20W 30W 40W 50W D Series Model Sonic conductance C dm3 s bar IN a OUT Existing model Existing model Existing model Existi...

Page 3: ...t to left Pressure unit psi Option With bracket With built in silencer for EXH port Made to Order Body color Red Flame resistant Pressure drop reduced by up to 73 0 5 0 0 1000 2000 3000 Outlet pressur...

Page 4: ...Metal V V V V e Flow direction Nil Flow direction Left to right V V V V R Flow direction Right to left V V V V f Pressure unit Nil Product label in SI units MPa V V V V Z 2 Product label in imperial u...

Page 5: ...ing Model Port size Flow rate characteristics IN OUT EXH IN R OUT OUT R EXH C dm3 s bar b Cv C dm3 s bar b Cv VHS20 D 1 8 1 8 4 0 0 41 1 1 3 7 0 42 1 1 1 4 5 8 0 31 1 4 3 8 0 42 1 1 VHS30 D 1 4 1 4 8...

Page 6: ...P2 A B C D E F G H J Single Double VHS20 D 1 8 1 4 1 8 48 5 51 7 23 40 37 28 42 17 5 40 21 VHS30 D 1 4 3 8 1 4 55 58 2 32 53 49 38 53 20 53 26 5 VHS40 D 1 4 3 8 1 2 3 8 69 7 73 9 41 3 70 63 52 71 29...

Page 7: ...03E1 D 1 pc Cross spacer Y34 03 D 1 pc Pressure relief 3 port valve VHS30 03 D 1 pc Combination example e Combination example q Combination example w Pressure relief 3 port valve Spacer with bracket R...

Page 8: ...5 40 55 18 9 26 7 50 VHS40 06 D Y600T D 6 2 140 60 115 50 70 20 11 31 2 8 70 VHS50 D Part no A B C D E Applicable model Y200 D 3 2 35 13 2 42 0 6 VHS20 D Y300 D 4 2 43 16 2 53 VHS30 D Y400 D 5 2 51 1...

Page 9: ...right V V V V R Flow direction Right to left V V V V f Pressure unit Nil Product label in SI units MPa V V V V Z 2 Product label in imperial units psi v 3 v 3 v 3 v 3 1 The pipe thread type for the EX...

Page 10: ...1 4 3 8 1 2 3 4 1 Torque 7 to 9 12 to 14 22 to 24 28 to 30 28 to 30 36 to 38 Precautions on Design Warning 1 Do not supply air pressure from ports other than the 1 P port The valve will malfunction w...

Page 11: ...ion failure Piping Warning 5 When an SMC One touch fitting is used refer to the operation manual for the One touch fitting 6 Silencer is recommended in the exhaust port When mounting a built in resin...

Page 12: ...ironments outside of the given specifications or use outdoors or in a place exposed to direct sunlight 2 Installation on equipment in conjunction with atomic energy railways air navigation space shipp...

Reviews: