REMEDY
Replace valve.
(9)
Check voltage. Replace pilot valve assembly.
(6)
Replace pilot valve assembly.
(7)
Adjust pressure so that pilot pressure will fall within operating pressure range during opretation.
(8)
-If worng oil used, completely air blow to remove oil and replace valve. After valve is replaced,
use turbine oil class 1 (ISO VG32).
No.
Remedy
(2)
Re-wire correctly.
(1)
Regulate voltage, so that the voltage at the time of the operationbecomes specifications range.
(11)
To remove foreign matter, clean the pipe by air blow. Replace valve.
(12)
Repair or replace actuators.
Isolate the valve and re-tighten the bolts.
(3)
Replace part.
(4)
Replace part or re-wire positively.
(5)
(13)
If no improvement is achieced in spite of the above countermeasure, inside of the valve may have some
abnomality. In this case, stop using the balbe immediately.
If any of followings are carried out, inside of the valve may have some failure. In this case, stop usig the
valve immediately.
(15)
Supply specified pressure to X port.
(Single solenoid, 3 position: 0.2 to 0.9 MPa, Double solenoid: 0.1 to 0.9 MPa)
-When a large quantity of drain is given and cannot carry out drain omission surely, install either
an auto-drain or a dryer. The valve should be replaced.
(14)
Lessen the oil supply amount to the degree that oill does not spout out of the exhaust port
[3(EB), 5(EA), PE port]. *In the case of N.O. specification, 1(P) port.
(10)
Protect the valve so that water does not splash the coil. Replace pilot valve assembly.
Voltage out of rated voltage has been used.
1.
Oil other than specified one has been lubricated.
2.
5.
Lubrication has been stopped intermediately, or lubrication was suspended temporary.
3.
In addition, in the case of trouble, please send it back to the supplier for repair or replacement.
Alien substance such as drain and particle got into. Drainor garbage invaded a valve.
6.
Prohibitted way of using the balbe which is written at "Precautions" section in this operation manual
was carride out excluding above -mentioned.
7.
Water splashed directely.
4.
Strong impact was given.