Change Direction of DIN 

Connector/Cable Entry 

 

 

Unscrew  retaining  screw,  pull  off  outer  cover,  rotate  connector 

block through 180°. Replace cover and tighten screw. 

 

Interface Regulator 

 
 

Specifications 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Note 1) Maximum operating pressure of solenoid valve is 0.9MPa. 

Note 2) Set the pressure within operating pressure range of   

solenoid valve. 

Note 3) Solenoid valve: Max. 50°C 

Note 4) Synthesized effective area with 2 position. 

Note 5) 

• Operate an interface regulator only by applying pressure 

from the “P” port of the base, except when using it as a 

reverse pressure valve. 

• To combine a pressure center valve and the A and B port 

pressure reduction interface regulator, use the ARBF4000 

model. 

• To combine a reverse pressure valve and an interface 

regulator, use the ARBF4000 model. The P port pressure 

reduction cannot be used. 

• When combining a double check valve and an interface 

regulator, use a manifold or sub-plate as a basis, and stack 

them in the following 

order; the perfect spacer → the 

interface regulator → the valve. 

• When a closed center valve is combined with the interface 

regulator’s A, B port regulation, note that it cannot be used 

for intermediate stops of a cylinder because there is 

leakage from relief port on the regulator. 

 

 

 

 

 

 

Type 01T with Terminal Block 

Remove junction cover of manifold, exposing terminal block 

attached to the manifold block. Lead wires from solenoid valve are 

connected with the terminals on upper side of terminal block. (On 

the terminal block, lead wire is connected with both A and B sides 

of solenoid valve in accordance with the corresponding markings 

A and B on the block.) 

Connect each lead wire of power side corresponding to respective 

solenoid valve on the lower terminal block. 

Terminal block wiring specifications is in accordance with COM. 

 

 

 

 

 

 

 

 

 
●Applicable terminal: 

1.25-3, 1.25-3S, 1.25Y-3N, 1.25Y-3S 

●Although “A–”, “B+” and “B–” marks are indicated on the terminal 

block, VFR4000 can be used as either “+COM” or “–COM”.

Lead Wire Connection 

A

B

P

Effective area at supply side (mm

2

)

P

A

35

31

26

S at P

1

= 0.7 MPa/P

2

=0.5MPa

P

B

31

31

24

Effective area at exhaust side(mm

2

)

A

EA

S at P

2

 = 0.5 MPa

B

EB

Ambient and fluid temperature

Port size for connection of pressure gauge

Weight (kg)

Interface regulator

Regulating port

Maximum operating pressure

Set pressure range

Rc 1/8

0.72

55

45

ARBF4050

1.0MPa

 

(1)

0.1

0.83MPa

 

(2)

-5

60

(No freezing)

 

(3)

Caution 

Caution 

Caution 

 

VFR4000  Series   

Specific  Product  Precautions  3 

 

Be sure to read this before handling. 

 

 

Summary of Contents for VFR4000 Series

Page 1: ...Doc No VFR4000 OMH0003 D PRODUCT NAME 5 Port Solenoid Valve MODEL Series VFR4000 Series...

Page 2: ...nstructions 2 3 Precautions on Design Selection 4 5 Mounting 5 Piping 5 6 Wiring 6 Lubrication 6 Air Supply 6 Operating Environment 7 Maintenance 7 Specific Product Precautions 8 to 11 Construction 12...

Page 3: ...quipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly Th...

Page 4: ...ailure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded...

Page 5: ...constant supply of vacuum Failure to do so may result in foreign matter sticking to the adsorption pad or air leakage causing the workpiece to drop 9 Ventilation Provide ventilation when using a valv...

Page 6: ...valves and external pilot type valves are used on the same manifold Additionally when compressed air within the pressure range of the established specifications is supplied to the external pilot type...

Page 7: ...ide the pilot valve causing malfunction or response delay So do not apply a large amount of oil When a large amount of oil needs to be applied use an external pilot type to put the supply air on the p...

Page 8: ...irst confirm that measures are in place to prevent workpieces from dropping run away equipment etc Then cut off the supply pressure and electric power and exhaust all compressed air from the system us...

Page 9: ...2 3 to 2 8 mm Type D Y 4 5 to 7 mm Applicable crimp terminal Type E T 1 25 3 1 25 3S 1 25Y 3N 1 25Y 3S Round shape or Y shape crimp terminal cannot be used for Type D DIN terminal block type VFR4 10...

Page 10: ...exhaust port leaving open How to Exchange Solenoid Valves Pilot Valve Assemblies How to exchange solenoid valves Loosen set screw and take solenoid valve out vertically otherwise it may cause damage...

Page 11: ...annot be used for intermediate stops of a cylinder because there is leakage from relief port on the regulator Type 01T with Terminal Block Remove junction cover of manifold exposing terminal block att...

Page 12: ...and COM Note 3 Station numbers are started from D side although connector is mounted on D or U Side Type 01F D sub Connector MIL standard type D connector Terminal 25 pins has wide exchangeability an...

Page 13: ...12 VFR4000 OMH0003 D VFR4000 Series Construction Be sure to read this before handling...

Page 14: ...13 VFR4000 OMH0003 D VFR4000 Series Construction Be sure to read this before handling...

Page 15: ...ly shifted 1 2 3 4 6 Coil splashed by water Low pilot pressure Intrusion of foreign matter Poor contact at contactor wire or connection part Low line voltage Higher voltage or wrong coil used Burnt co...

Page 16: ...n this case stop usig the valve immediately 15 Supply specified pressure to X port Single solenoid 3 position 0 2 to 0 9 MPa Double solenoid 0 1 to 0 9 MPa When a large quantity of drain is given and...

Page 17: ...1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL https www smcworld com Note Specifications are subject to change without prior notice and any obligation on the p...

Reviews: