How to use DIN terminal connector
Disassembly
1) After loosening the thread (1), then if the housing (2) is pulled
in the direction of the thread (1), the connector will be
removed from the body of equipment (solenoid, etc.).
2) Pull the thread (1) out of the housing (2).
3) On the bottom part of the terminal block (3), there’s a cut-off part
(9). If a small flat head screwdriver is inserted between the
opening in the bottom, terminal block (3) will be removed from the
housing (2). (Fig. 1)
4) Remove the cable gland (4) and plain washer (5) and rubber
seal (6).
Wiring
1) Passing through the cable (7), cable gland (4), plain washer
(5), rubber seal (6) in this order, and then insert into the
housing (2).
2) From the terminal block (3), loosen the screw (11), then pass
the lead wire (10) through, then again tighten the screw (11).
Note 1) The tightening torque should be within 0.5Nm +/- 15%.
Note 2) Cable (7) external:
φ
6 to
φ
8 mm.
Note 3) Crimped terminal like round-shape or Y shape cannot be
used.
Assembly
1) Passing cable gland (4), washer (5), rubber seal (6),
housing (2) in this order through cable (7) and connect
to terminal block (3) and then set the terminal block (3)
to the housing (2).
(Push it down until you hear the click sound.)
2) Putting rubber seal (6), plain washer (5), in this order into the
cable introducing slit on the housing (2), then further tighten
the cable gland (4) securely.
3) Insert the gasket (8) between the bottom part of terminal block
(3) and a plug attached to equipment, and then screw (1) in
from the top of the housing (2) to tighten it.
Note 1) The tightening torque should be within 0.5Nm +/- 20%.
Note 2) Connector orientation can be changed by 180 degrees
depending on how to assemble the housing (2) and the
terminal block (3).
DIN terminal connector
Description
Part no.
DIN connector
B1B09-2A6(standard)
Light/Surge Voltage Suppressor
AC
<
Surge voltage suppressor
>
Grommet
(
G,H
)
<
Light/Surge voltage suppressor
>
Grommet terminal (E),Conduit terminal (T)
DIN terminal (D)
When 100 VAC or more
When 24 VAC or less
DC
<
Surge voltage suppressor
>
Grommet
(
G,H
)
<
Light/Surge voltage suppressor
>
Grommet terminal (E),Conduit terminal (T)
DIN terminal (D)
When 100 VDC or more
When 24 VDC or less
Varistor
Coil
Varistor
Coil
Red(
+
)
Black(
-
)
Coil
Diode
Caution
Varistor
Coil
Varistor
Coil
Neon bulb
Varistor
Coil
Neon bulb
Fig. 1
VEX5 Series
Specific Product precautions 1
Be sure to read this before handling.
- 7 -
No.VEX
∗∗∗∗