2

INTENDED CONDITIONS OF USE

2.1 Standard specifications VDW 10/20/30

Valve specifications

Note 1) Consult SMC when used under conditions which may cause condensation on the

exterior of the product.

Note 2) When used with pure water, select "L" (stainless steel, FKM) for the material

type.

Note 3) Since AC coil specifications include a rectifying device, there is no difference in

power consumption for starting and holding. 

In case of 110/220VAC, VDW10

is 3W and VDW20/30 is 3.5W.

Note 4) Vibration resistance … No malfunction when tested with one sweep of 5 to 200Hz

in the axial direction and at a right angle to the armature, in both energized and
deenergized.states. Impact resistance … No malfunction when tested with a
drop tester in the axial direction and at a right angle to the armature, one time
each in energized and deenergized states.

Note 5) Consult SMC regarding drip-proof specifications (equivalent to IP54).

2.2 Piping

When piping to an N.O. port, be sure to perform piping work while holding the socket
with a wrench or other tool.

2.3 Circuit Symbols

3

INSTALLATION

WARNING

Do not install unless the safety instructions have been read and understood.

3.1 Environment

WARNING

Do not use in an environment where the product is directly exposed to corrosive
gases, chemicals, salt water, water or steam.

Do not use in an explosive atmosphere.

The product should not be exposed to prolonged sunlight. Use a protective cover.

Do not mount the product in a location where it is subject to strong vibrations
and/or shock. Check the product specifications for above ratings.

Do not mount the product in a location where it is exposed to radiant heat.

Read this manual before using this product.

The information within this document is to be used by pneumatically trained
personnel only.

For future reference, please keep manual in a safe place.

This manual should be read in conjunction with the current catalogue.

1

SAFETY

1.1 General recommendation

These safety instructions are intended to prevent a hazardous situation and/or
equipment damage. These instructions indicate the level of potential hazard by label of
"Caution", "Warning" or "Danger". To ensure safety, be sure to observe ISO4414
(Note1), JIS B 8370 (Note2) and other safety practices.

Note 1:ISO 4414:Pneumatic fluid power - General rules relating to systems. 
Note 2:JIS B 8370:Pneumatic system axiom.

WARNING

The compatibility of pneumatic equipment is the responsibility of the person
who designs the pneumatic system or decides its specifications.

Since the products specified here are used in various operating conditions, their
compatibility for the specific pneumatic system must be based on specifications or
after analysis and/or tests to meet your specific requirements.

Only trained personnel should operate pneumatically operated machinery
and equipment.

Compressed air can be dangerous if an operator is unfamiliar with it. Assembly,
handling or repair of pneumatic systems should be performed by trained and
experienced operators.

Do not service machinery/equipment or attempt to remove components
until safety is confirmed.

Inspection and maintenance of machinery/equipment should only be performed
after confirmation of safe locked-out control positions.

When equipment is to be removed, confirm the safety process as mentioned
above. Switch off air and electrical supplies and exhaust all residual compressed
air in the system.

Before machinery/equipment is re-started, ensure all safety measures to prevent
sudden movement of cylinders etc. (Bleed air into the system gradually to create
backpressure, i.e. incorporate a soft-start valve).

Contact SMC if the product is to be used in any of the following conditions:

Conditions and environments beyond the given specifications, or if product is used
outdoors.

Installations on equipment in conjunction with atomic energy, railway, air
navigation, vehicles, medical equipment, food and beverage, recreation
equipment, emergency stop circuits, press applications, or safety equipment.

An application, which has the possibility of having negative effects on people,
property, or animals, requiring special safety analysis. 

CAUTION:

Ensure that the air supply system is filtered to 5 micron.

1.2 Conformity to standard

This product is certified to and complies with the following standards:

3.2 Piping

CAUTION

Before piping make sure to clean up chips, cutting oil, dust etc.

When installing piping or fitting into a port, ensure that sealant material does not
enter the port inside. When using seal tape, leave 1.5 to 2 threads exposed on the
end of pipe/fitting. 

CAUTION

The maximum operating pressure differential differs depending on the flow direction of
the fluid. If the pressure differential at each port exceeds the values in the table below,
valve leakage may occur.

3.3 Electrical connection

CAUTION:

When DC power is connected to a solenoid valve equipped with light and/or surge
voltage suppressor, check for polarity indications.

For polarity indications:

No diode to protect polarity: if polarity connection is wrong, the diode in the
valve or switching device at control equipment or power supply may be
damaged.

With diode to protect polarity: if polarity connection is wrong, the valve does
not switch.

3.4 Wiring

CAUTION:

As a rule, use electrical wire of 0.5 to 1.25mm

or more. Furthermore, do not allow

excessive force to be applied to the lines.

Use electrical circuits which do not generate chattering in their contacts.

Use voltage which is within ±10%  of the rated voltage, In cases of a DC power
supply where emphasis is placed on responsiveness, stay within ±5% of the rated
value. The voltage drop is the value in the lead wire section connecting the coil.

Installation and Maintenance Manual

Series VDW 10/20/30: 2 port, VDW200/300: 3 port 
Compact Direct Operated Solenoid Valve 
for Water and Air

CAUTION:

Operator error could result in injury or equipment

damage. 

WARNING:

Operator error could result in serious injury or loss of life.

DANGER:

In extreme conditions, there is a possible result of

serious injury or loss of life.

X

Note1) Indicate the maximum operating pressure differential between ports 2 and 3.

Note2) When applying pressure from port 2, be careful to avoid vibration and impacts

etc.

Note3) For  low vacuum specifications, the operating pressure range is 1 Torr 

(1.33 102Pa) to 1.0Mpa.

The grommet is the only available option. 

CAUTION

3.5 Mounting

WARNING

If air leakage increases or equipment does not operate properly, stop
operation.

After mounting is completed, comfirm that it has been done correctly by
performing a suitable function test.

Do not apply external force to the coil section.

When tightening is performed, apply a wrench or other tool to the outside of the
piping connection parts.

Do not warm the coil assembly with a heat insulator, etc.

Use tape and heaters, etc., for freeze prevention on the piping and body only.
They can cause the coil to burn out.

Secure the product except in the case of steel piping and copper fittings.

Avoid sources of vibration, or set the arm from the body to the minimum
length so that resonance will not occur.

Instruction manual

Mount the product after reading the manual carefully and understanding its
contents. Also keep the manual where it can be referred to as necessary.

Painting and coating

Warning and specifications printed or pasted on the product should not be
erased, removed or covered up.

3.6 Manifold Mounting

Manifold additions

1. Install a passage pipe assembly in between the manifold bases to be

added.

2. Connect the respective manifold bases with a connecting plate

assembly. (Tightening torque: 0.9±0.1N.m)

3. 

Attach brackets to the manifold bases. {When equipped with

brackets} (Tightening torque: 0.9±0.1N.m)

VDW - TFI29GB

EMC Directive 89/336/EEC

EN61000-6-2
EN55011

Low Voltage Directive 93/68/EEC

DIN VDE 0580

Valve construction

Direct operated poppet

Fluid Note 2)

Water (except waste water or agricultural water), Air, Low vacuum

Withstand pressure Mpa

2.0

Ambient temperature °C

-10 to 50

Fluid temperature °C

1 to 50 (with no freezing)

Environment

Location without corrosive or explosive gases

Valve leakage cm3/min

0 (with water pressure) 

1 (with air pressure)

Mounting orientation

Unrestricted

Vibration/Impact m/s2 Note 4)

30/150

Rated voltage

24VDC, 12VDC, 100VAC, 110VAC, 200VAC, 220VAC (50/60Hz)

Allowable voltage fluctuation %

±10% of rated voltage

Coil insulation type

Class B

Enclosure Note 5)

Dust proof (equivalent to IP40)

Power consumption W Note 3)

2.5 (VDW10), 3 (VDW20/30/200/300)

V

a

lv

e specifications

Coil 

specifications

Lead wire

OUT

IN

N.O.

Socket

Cover

Lead wire

N.C.

IN

Thread

Appropriate tightening torque (Nm)

M5

By hand + 1/6 turn with the wrench (1/4 turn for miniature fittings)

Rc 1/8

7 to 9 

Rc 1/4

12 to 14

Model

Orifice size mm

Operating pressure

Pressure port 1

Pressure port 2

(2)

range Mpa

(3)

VDW10

ø1

0.9

0.4

ø1.6

0.4

0.2

VDW20

ø1.6

0.7

0.2

ø2.3

0.4

0.1

0 to 1.0

ø3.2

0.2

0.05 

VDW30

ø2

0.8

0.2

ø3

0.4

0.1

ø4

0.2

0.05

Maximum operating pressure differential Mpa

Model

Orifice size mm

Operating pressure

Pressure port 1

Pressure port 2,3

(1)(2)

range Mpa

(3)

VDW200

ø1

0.9

0.3

ø1.6

0.7

0.1

VDW300

ø2

0.8

0.2

ø3

0.4

0.1

0 to 1.0

ø4

0.2

0.05 

Maximum operating pressure differential Mpa

Page 1 of 2

N.C.

VDW 10/20/30

VDW 200/300

1

2