![SMC Networks TigerSwith 100 SMC6924VF Installation Manual Download Page 50](http://html1.mh-extra.com/html/smc-networks/tigerswith-100-smc6924vf/tigerswith-100-smc6924vf_installation-manual_1300432050.webp)
M
AKING
N
ETWORK
C
ONNECTIONS
4-2
VF-45 Fiber Connections
Each device requires a 62.5/125 micron or 50/125 micron
multimode fiber optic cable with VF-45 connectors at both ends.
1. Remove and keep the VF-45 port’s plastic cover. When not
connected to a fiber cable, the cover should be replaced to
protect the optics.
2. Check that the fiber terminators are clean. You can clean the
cable plugs using an appropriate VF-45 cleaning kit. Dirty fiber
terminators on fiber optic cables will impair the quality of the
light transmitted through the cable and lead to degraded
performance on the port.
3. Connect one end of the cable to the VF-45 port on the switch
and the other end to the VF-45 port on the other device. Since
VF-45 connectors are keyed, the cable can be attached in only
one orientation.
4. As each connection is made, check the Link LED on the
switch’s front panel for the corresponding port to be sure that
the connection is valid.
You can run a fiber link up to 2 km (1.24 mi.) in full-duplex mode,
and 412 m (1351 ft.) in half-duplex mode. However, note that
power budget and timing constraints must also be considered
when calculating the maximum cable length for your specific
environment.
Summary of Contents for TigerSwith 100 SMC6924VF
Page 2: ......
Page 14: ...TABLE OF CONTENTS viii...
Page 28: ...ABOUT THE TIGERSWITCH 100 1 14...
Page 38: ...NETWORK PLANNING 2 10...
Page 56: ...MAKING NETWORK CONNECTIONS 4 8...
Page 60: ...TROUBLESHOOTING A 4...
Page 68: ...CABLES B 8...
Page 78: ...ORDERING INFORMATION D 2...
Page 89: ......