T
ROUBLESHOOTING
A-3
3. Change your baud rate to 115200 bps, and press Enter to
enable download mode. From the terminal emulation program,
select the file you want to download, set the protocol to
XModem, and then initialize downloading.
Notes: 1.
If you use Windows HyperTerminal, disconnect
and
reconnect
to enable the new baud rate.
2.
The download file should be an SMC6924VF binary file
from SMC; otherwise the agent will not accept it. The
file naming convention is:
Runtime program:
Agent-Vx.yz,
POST program:
Boot-Vx.yx, and
Mainboard program: 8051-Vx.yz
4. After the file has been downloaded, the console screen will
display information similar to that shown below. Press “s” to
start the management interface, change the baud rate back to
19200, and press Enter. The Logon screen will then appear.
For details on managing the switch, refer to Chapter 2 for
information on the out-of-band console interface, or Chapter 3 for
information on the Web interface.
XModem Download to DRAM buffer area 0x00200000:
... SUCCESS !
Verifying image in DRAM download buffer 0x00200000... SUCCESS !
Update FlashROM Image at 0x02880000 ... SUCCESS !
(D)ownload another Image or (S)tart Application: [S] s
Change Baud Rate to 19200 and Press <ENTER>.