SMC Networks SFE Series Operation Manual Download Page 3

-2- 

 
 

         

Clean Exhaust Filter 

       

 Safety Instructions

 

 

These safety instructions are intended to prevent hazardous situations and/or equipment damage.

 

These instructions indicate the level of potential hazard with the labels of “Caution,” “Warning” or “Danger.”

 

They are all important notes for safety and must be followed in addition to International Standards 
(ISO/IEC)

*1)

, and other safety regulations.

 

*1) ISO 4414: Pneumatic fluid power -- General rules relating to systems.

 

   

ISO 4413: Hydraulic fluid power -- General rules relating to systems.

 

   

IEC 60204-1: Safety of machinery -- Electrical equipment of machines .(Part 1: General requirements)

 

   

ISO 10218-1992: Manipulating industrial robots -Safety.

                                                                                 

 

 

 etc.

 

     

     
 
 

Caution

 

Caution

 indicates a hazard with a low level of risk which, if not avoided, could result

in minor or moderate injury.

 

 
 

Warning

 

Warning

 

indicates a hazard with a medium level of risk which, if not avoided, could 

result in death or serious injury.

 

 
 

Danger

 

Danger

 

indicates a hazard with a high level of risk which, if not avoided, will result 

in death or serious injury.

 

 

Warning

 

1. The compatibility of the product is the responsibility of the person who designs the equipment or 

decides its specifications.

 

Since the product specified here is used under various operating conditions, its compatibility with specific 
equipment must be decided by the person who designs the equipment or decides its specifications based on 
necessary analysis and test results.   
The expected performance and safety assurance of the equipment will be the responsibility of the person who 
has determined its compatibility with the product.   
This person should also continuously review all specifications of the product referring to its latest catalog 
information, with a view to giving due consideration to any possibility of equipment failure when configuring the 
equipment.

 

2. Only personnel with appropriate training should operate machinery and equipment.

 

The product specified here may become unsafe if handled incorrectly.

 

The assembly, operation and maintenance of machines or equipment including our products must be 
performed by an operator who is appropriately trained and experienced.

 

3. Do not service or attempt to remove product and machinery/equipment until safety is confirmed.

1.The inspection and maintenance of machinery/equipment should only be performed after measures to   

prevent falling or runaway of the driven objects have been confirmed.

 

2.When the product is to be removed, confirm that the safety measures as mentioned above are implemented
    and the power from any appropriate source is cut, and read and understand the specific product precautions
    of all relevant products carefully.

 

3. Before machinery/equipment is restarted, take measures to prevent unexpected operation and malfunction.

4. Contact SMC beforehand and take special consideration of safety measures if the product is to 

be used in any of the following conditions.

 

1. Conditions and environments outside of the given specifications, or use outdoors or in a place exposed to 
  direct sunlight.

 

2. Installation on equipment in conjunction with atomic energy, railways, air navigation, space, shipping, 

  vehicles, military, medical treatment, combustion and recreation, or equipment in contact with food and 
  beverages, emergency stop circuits, clutch and brake circuits in press applications, safety equipment or 
  other applications unsuitable for the standard specifications described in the product catalog.

 

3. An application which could have negative effects on people, property, or animals requiring special safety   

analysis.

 

4.Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a 

mechanical protective function, and periodical checks to confirm proper operation. 

Summary of Contents for SFE Series

Page 1: ...Document No FGX OM R008 B PRODUCT NAME Clean Exhaust Filter Series Product Number SFE Series SFE11 SFE42 SFE52 SFE53 SFE73 SFE3A SFE4B SFE5C SFE7D SFE3F SFE4G SFE5H SFE7J ...

Page 2: ... 1 Contents Safety Instructions 2 Specific Product Precautions for SFE Series 4 Specifications 5 ...

Page 3: ...ty of equipment failure when configuring the equipment 2 Only personnel with appropriate training should operate machinery and equipment The product specified here may become unsafe if handled incorrectly The assembly operation and maintenance of machines or equipment including our products must be performed by an operator who is appropriately trained and experienced 3 Do not service or attempt to...

Page 4: ...our responsibility a replacement product or necessary parts will be provided This limited warranty applies only to our product independently and not to any other damage incurred due to the failure of the product 3 Prior to using SMC products please read and understand the warranty terms and disclaimers noted in the specified catalog for the particular products 2 Vacuum pads are excluded from this ...

Page 5: ...tening torque 0 2 Nm 3 Do not mount the product in a place where dust will be stirred up by the exhaust air from the product and affect peripheral equipment 4 Do not mount the product in a location where air from the product will be directly exhausted to the workpiece 5 Check the dimensions to select the correct product size as a fitting may interfere with the product and it may not be possible to...

Page 6: ...e touch fitting 5 5g 8g 16g 24g Mass of bracket g 1 2g 2 5g 3 5g 5 5g Applicable tube material Note 6 One touch fitting type PFA Polyolefin Soft polyolefin Polyurethane Product life as a guide 2 years after using the product or when the back pressure of SFE reaches 0 1 MPa When the system fails to operate normally due to clogging Packaging Hermetically sealed anti static double packaging Male thre...

Page 7: ...ounted to e g solenoid valve cylinder Note 5 Materials which are marked with are for use with One tough fitting type only Note 6 Polyurethane tubing is soft and may bend when inserted into the fitting To prevent bending hold the tube at the base and securely connect it into the fitting Dimensions 1 SFE11 2 SFE42 52 53 73 3 SFE3A Dimensions SFE42 52 53 73 Model A B C D SFE42 10 62 16 5 R1 8 SFE52 1...

Page 8: ... 6 SFE4G 5H 7J Dimensions SFE4B 5C 7D Model A B C SFE4B 6 73 16 5 SFE5C 8 84 20 5 SFE7D 10 94 24 Dimensions SFE4G 5H 7J Model A B C SFE4G 6 68 5 16 5 SFE5H 8 79 20 5 SFE7J 10 89 24 Applicable tube O D ØA Applicable tube O D Ø4 ...

Page 9: ...2 SFE BR4 5 7 Dimensions SFE BR4 5 7 Model A B C D E F G H J SFE BR4 30 16 7 4 5 7 5 24 5 17 15 5 19 5 SFE BR5 30 10 8 2 4 5 8 1 29 20 18 23 SFE BR7 34 14 7 35 4 5 9 8 35 24 20 27 3 The values inside the brackets are given as a guide ...

Page 10: ...g type SQ Accessories added Bracket 4 14 1 Sotokanda Chiyoda ku Tokyo 101 0021 JAPAN Tel 81 3 5207 8249 Fax 81 3 5298 5362 URL http www smcworld com Note Specifications are subject to change without prior notice and any obligation on the part of the manufacturer 2013 SMC Corporation All Rights Reserved ...

Reviews: